bob from maine
User Rank
Platinum
Re: Automotive Ground Straps
bob from maine   2/6/2013 1:42:52 PM
NO RATINGS
The comment about small ground straps from the body to the engine block is a valid point. If you connect the negative cable to the engine block - not the frame -  you will be fine. Making a good electrical contact with a jumper cable clamp and a rusted or painted part of a steel engine block may be difficult so you may have to choose the connection point carefully. Providing an adequate ground on moving equipment has proven to be a diffuclt challenge to meet. Imagine the static that used to build-up on cars in the 50's. Eventually methods were developed to allow the static charge to bleed-off, but before then, passing a bill to a toll attendant could cause some fairly dramatic shocks.

Critic
User Rank
Platinum
Automotive Ground Straps
Critic   1/28/2013 4:51:55 PM
NO RATINGS
Instructions for jump-starting vehicles typically recommend that the last jumper cable connection be made to the chassis of the vehicle, rather than to the battery itself.  This is supposed to prevent a spark near the battery vents where hydrogen gas could ignite.  This is not bad advice to prevent a hydrogen explosion, but there is generally very little risk of an explosion (safety conscious people:  bash me now).

If the dead/low battery is no longer capable of sourcing enough current to crank the engine after a few minutes of charging, then a different kind of fire hazard is created by following the "safe" instructions.  The heavy-gauge negative cable from the battery typically connects to the engine block, because the starter usually draws more current than any other electrical device in most (production, non-electric, non-hybrid) cars and trucks.  There is usually a lighter-gauge strap from the engine to body/chassis.  If you connect the jumper cable to the chassis, and the cranking current must flow through the jumper cable, that is, if it is not sourced by the dead/low battery, then cranking current flows through the strap.

In this situation, the strap gets very hot, very quickly.  I witnessed a not-so-helpful tow-truck driver try to jump start my truck and the procedure melted the ground strap and started a small fire.

One reason this doesn't happen more often is that the jumper cables most people own are of small wire gauge, so there is significant voltage drop across the cable during cranking.

Does anyone know of a safe, non-destructive procedure for jump starting???

Tool_maker
User Rank
Platinum
Less than Expert Customers
Tool_maker   1/28/2013 1:02:50 PM
NO RATINGS
  I just love it when customers or end users make changes, without understanding the logic of what they have changed, and then blame the designer for producing a defective part. This problem runs across the full spectrum and is not confined to weak minded people. If two is good, why three must be better. I am sure this vehicle would perform better with a different tire size. Etc, etc.

  Great job of trouble shooting and you did not lose a customer, you solved a problem yet to come.

William K.
User Rank
Platinum
Re: Grounds, shields, and ungrounded grounds
William K.   1/25/2013 5:32:12 PM
NO RATINGS
Wit our sensors, which detected shock waves traveling in the metal, I found that every installation needed to either pick up the substrate that the sensor was mounted on, or else have a very thin insulkated shield bonded to the substrate, with the sensor then bonded to the shield. This avoided there ever being more than a few volts between the sensor and the conductive surface that it was mounted on. That might be a problem for strain gauges, I have not studied it. Possibly a rigid enoug epoxy would work.

tekochip
User Rank
Platinum
Re: Grounds, shields, and ungrounded grounds
tekochip   1/25/2013 8:42:19 AM
NO RATINGS
Good point William, in practice the load cells were never attached to the shield because of problems with ground loops.  Some of the load cells were trailer hitches or physical links between the wagon body and wagon frame.  Tail lights, alarm horns and other accessories would wreak havoc with the signal if the shields were terminated.

William K.
User Rank
Platinum
Grounds, shields, and ungrounded grounds
William K.   1/24/2013 7:15:35 PM
NO RATINGS
This is an interesting example of one of the problems that will pop up when the efforts to keep low level signals in the low level realm are inadequate. I can understand that it was cheaper to simply glue the strain gauge to the axle, but the shiels of the cable should have been connected to that axle, or another conductor, if not the shield. MY reasoning is that aside from the voltage build up, the conductive axle is a good candidate to pick up a lot of noise and couple it to the strain guage. I learned all about the coupling of undesired signals while working with a non-strain-gage pickup as part of a product development project. Compensating cor the mount material potential is vital. 

The two solution options would have been to either ground the axle to the input circuit, or to float the input circuit from all other potentials, but that would be difficult and expensive.

Charles Murray
User Rank
Blogger
Re: Customer Modifications
Charles Murray   1/24/2013 6:53:17 PM
NO RATINGS
I remember that story, Jenn. I liked it for two reasons. First, it was a clever solution. Second, instead of coming up with some costly, convulted solution, they simply stopped testing their phones when a frieght train would pass.

dougspair
User Rank
Gold
Re: Customer Modifications
dougspair   1/24/2013 5:00:57 PM
NO RATINGS
 On the subject of ground straps, I've seen missing ground straps on motor vehicles, and what often happens is the cranking current for the starter motor will go through the next best conductor, often the driveshaft U-Joints, fries them pretty well.

eafpres
User Rank
Gold
Customer Service
eafpres   1/24/2013 2:11:22 PM
NO RATINGS
Hi Chip--great story.  It is always challenging supporting customers in the field.  You were lucky to get the parts back.

Once I was involved with design, production, and then support of an antenna module for commercial telematics.  It consisted of an amplified GPS patch antenna integrated to a cellular omnidirectional antenna printed on an FR4 PCB.  There was a long cable pigtail to allow the installer to locate the antenna in a good but hidden place in vehicles.  Most often, it was placed under the dash on top of wire bundles or air ducts etc.

Two support challenges were memorable.  I don't need to give all the details, just the solutions.  Case 1: "We recommend you do not locate the antenna inside the glove box as the antenna won't perform well inside of a metal enclosure".  Case 2: We added a label "This Side Up" to ensure the GPS patch was facing the sky, not the ground.

DanSchwartz
User Rank
Iron
Re: Customer Modifications
DanSchwartz   1/24/2013 9:38:06 AM
NO RATINGS
@Jennifer: My favorite Sherlock Ohms article so far is Noise Messed With the Automation System; which led to this popular article Surge Impedance: Why you see the spark when you unplug your iron I wrote to explain the underlying engineering principles.

Dan Schwartz,
Editor, The Hearing Blog
All incoming LinkedIn colleague and Facebook friend requests are welcome~

Page 1/2  >  >>


Partner Zone
Latest Analysis
Self-driving vehicle technology could grow rapidly over the next two decades, with nearly 95 million “autonomous-capable” cars being sold annually around the world by 2035, a new study predicts.
MIT’s Senseable City Lab recently announced the program’s next big project: “Local Warming.” The concept involves saving on energy by heating the occupants within a room, not the room itself.
The fun factor continues to draw developers to Linux. This open-source system continues to succeed in the market and in the hearts and minds of developers. Design News will delve into this territory with next week's Continuing Education Class titled, “Introduction to Linux Device Drivers.”
Dean Kamen tells an audience at MD&M East 2014 how his team created the DEKA Arm to meet DARPA's challenge to design a better prosthetic arm for wounded veterans.
The new draw-it-on-a-napkin is the CAD program. As CAD programs become more ubiquitous and easier to use, they have replaced 2D sketching for early concepting.
More:Blogs|News
Design News Webinar Series
7/23/2014 11:00 a.m. California / 2:00 p.m. New York
7/17/2014 11:00 a.m. California / 2:00 p.m. New York
6/25/2014 11:00 a.m. California / 2:00 p.m. New York
5/13/2014 10:00 a.m. California / 1:00 p.m. New York / 6:00 p.m. London
Quick Poll
The Continuing Education Center offers engineers an entirely new way to get the education they need to formulate next-generation solutions.
Aug 4 - 8, Introduction to Linux Device Drivers
SEMESTERS: 1  |  2  |  3  |  4  |  5  |  6


Focus on Fundamentals consists of 45-minute on-line classes that cover a host of technologies. You learn without leaving the comfort of your desk. All classes are taught by subject-matter experts and all are archived. So if you can't attend live, attend at your convenience.
Next Class: August 12 - 14
Sponsored by igus
Learn More   |   Login   |   Archived Classes
Twitter Feed
Design News Twitter Feed
Like Us on Facebook

Sponsored Content

Technology Marketplace

Copyright © 2014 UBM Canon, A UBM company, All rights reserved. Privacy Policy | Terms of Service