Toilet valve water hammer
btlbcc   12/7/2012 3:21:30 PM
NO RATINGS
I had a similar problem recently.  The fill valve (a Watermaster brand) was intermittently leaking, and for some reason (I didn't bother to autopsy the old valve, which I installed back in 1996, and which performed faithfully for nearly 15 years - no complaints) this would trigger the fill action; the float (or something internal) would stop the flow and then it would start again.  Since this particular model of the valve shut off with a snap, there was a definite water hammer, at a frequency of about 2 cycles per second. This osillation could be started by a sudden pressure drop in the system (such as the washing machine fill valve opening) or it could self-start (usually about 3AM).

Needless to say, this was not likely to improve the plumbing system.  I could generally stop it for a while (days) by jiggering the float valve arm, but a replacement valve solved the problem completely. 

If there is a lesson from all this, it is that, in most houses, the toilet fill valve is the only automatic system in the plumbing.  Everything else - washing machines, dishwashers, various faucets, etc. tends to operate only upon command.  The toilet fill valve will operate whenever the water level in the tank drops or (in my case) from an internal malfunction.  Way back when, I worked as a plumber for a few years, and the most common problem was toilet repair, so I learned to hate fixing toilets!

bob from maine
User Rank
Platinum
Re: Water Hammer stopped but not cured.
bob from maine   12/7/2012 10:15:31 AM
NO RATINGS
In all the houses and remodels I have done, I've always required my plumber to install water hammer arrestors like the ones described by Sliderulefarmer in the hot/cold lines adjacent to every electrically operated valve; washing machine, dish washer. Water hammer probably destroys more water mains and causes more damage inside houses than most other single events. I've seen 30 ton fire trucks actually moved sideways when a valve was incorrectly slammed shut on a 5" line. Good observation, connecting the toilet valve and knocking noise.

SlideRuleFarmer
User Rank
Iron
Water Hammer stopped but not cured.
SlideRuleFarmer   12/7/2012 10:02:42 AM
NO RATINGS
While you did stop the hammering by finding the source of initially oscilating valve, the true problem lies in poorly installed lines. Having worked under a great plumbers watchful eye, he always made sure we secured the lines throughout the walls. Water hammering is started by a valve opening and closing quickly, toilet, washer, dish washer, even shower valves can do this at times, but the real noise comes from the pipes banging on the studs and walls somewhere in the house. To really stop this from ever happening again you need to install a water hammer arrester. Sounds complex but it is simply a short piece of capped pipe (<1 foot) installed vertically somewhere in the system, being vertical it holds a small air pocket at the top that dampens & eliminates water hammering. You need to install one on both the hot and cold lines. With the new PEX piping this has become less of a problem as PEX seems to have a little give in it that dampens the hammering.

<<  <  Page 2/2


Partner Zone
Latest Analysis
Do you see a perfectly good design and still insist on changing it? You might be an engineer.
A bold, gold, open-air coupe may not be the ticket to automotive nirvana for every consumer, but Lexus’ LF-C2 concept car certainly turned heads at the recent Los Angeles Auto Show. What’s more, it may provide a glimpse of the luxury automaker’s future.
Perhaps you didn't know that there are a variety of classes, both live and archived, offered via the Design News Continuing Education Center (CEC) sponsored by Digi-Key? The best part – they are free!
Engineer comic Don McMillan explains the fun engineers have with team-building exercises. Can you relate?
The complexity of diesel engines means optimizing their performance requires a large amount of experimentation. Computational fluid dynamics (CFD) is a very useful and intuitive tool in this, and cold flow analysis using CFD is an ideal approach to study the flow characteristics without going into the details of chemical reactions occurring during the combustion.
More:Blogs|News
Design News Webinar Series
12/11/2014 8:00 a.m. California / 11:00 a.m. New York
12/10/2014 8:00 a.m. California / 11:00 a.m. New York
11/19/2014 11:00 a.m. California / 2:00 p.m. New York
11/6/2014 11:00 a.m. California / 2:00 p.m. New York
Quick Poll
The Continuing Education Center offers engineers an entirely new way to get the education they need to formulate next-generation solutions.
Jan 12 - 16, Programmable Logic - How do they do that?
SEMESTERS: 1  |  2  |  3  |  4  |  5  |  67


Focus on Fundamentals consists of 45-minute on-line classes that cover a host of technologies. You learn without leaving the comfort of your desk. All classes are taught by subject-matter experts and all are archived. So if you can't attend live, attend at your convenience.
Learn More   |   Login   |   Archived Classes
Twitter Feed
Design News Twitter Feed
Like Us on Facebook

Sponsored Content

Technology Marketplace

Copyright © 2014 UBM Canon, A UBM company, All rights reserved. Privacy Policy | Terms of Service