Re: LAMP SOCKETS, etal....
Jon Titus   4/23/2012 6:54:46 PM
NO RATINGS
Good to know, Larry.  Thankfully I found a good quality socket, but I also have some 2-56 hardware handy, too.

Larry M
User Rank
Platinum
Re: LAMP SOCKETS, etal....
Larry M   4/23/2012 10:36:08 AM
NO RATINGS
Jon Titus wrote: " I also thought about running a 2-56 bolt through the brass tubing, tightening it and locking it in place. I might do that if I can't find an Eagle or Leviton replacement with a solid connection. We'll see..."

 

Jon, I've done this. I had to drill through the rivet, thinning it's walls, for the 2-56 machine screw to clear. The repair was easy and successful.

Jon Titus
User Rank
Blogger
Re: new vs old
Jon Titus   4/12/2012 5:29:17 PM
Yes, aluminum has a higher resistivity than copper, but the resistance overall is so low compared to the load resistance that you lose an insignificant amount of energy in either type of wire. Instead of WD-40, try the silicone grease I recommended in an earlier blog post.  WD-40 is a water displacement agent used to help prevent corrosion.

Tool_maker
User Rank
Platinum
new vs old
Tool_maker   4/12/2012 4:56:02 PM
NO RATINGS
I read so many posts in this publication about the failures of new elecric devices that I have to wonder if any manufacturer knows how to make reliable electrics today. I am a fan of estate sales and have a great deal of luck with refurbishing old stuff.

On the aluminum wiring, I heard years ago that it has a higher resistance than copper, so powering the exact same devices in a house with aluminum wire will cost more than if the wire is copper. Does anyone know if that is correct?

I also replace all "bulb down sockets" with pocelain. Ceiling fans for example and put a drop of WD 40 on aluminum light bulb bases. It seems to make bulbs easier to change.

Bernie
User Rank
Iron
Poor lamp socket design
Bernie   4/11/2012 3:28:48 PM
NO RATINGS
Toward the end of the 1960's, aluminum was used for house wiring.  There were fires, initially in travel homes, but later, regular homes also experienced fires.  The cause was aluminum wires.  Aluminum has two properties that caused this problem.  First, it is a soft metal, and second, its oxide is a tough film, and an insulator.  In the case of the home wiring, vibration in mobile homes during delivery or driving, loosened the screws in the receptacle and socket contacts.  This was followed by oxidation and a reduction in the contact area because some of it was oxidized and became an insulator.  The result was heating at the contacts.

A similar problem arose with stationary homes.  Here, since the aluminum wires were softer than the brass contacts, if the wires at the contacts heated enough, the aluminum would deform because of the restriction of the contact screws.  When the contact cooled, the aluminum would contract and now there would be space where the aluminum could oxidize.

It is possible that this mechanism was the cause of the failed socket.

Jon Titus
User Rank
Blogger
Re: LAMP SOCKETS, etal....
Jon Titus   4/11/2012 11:53:56 AM
Even aluminum-on-aluminum sockets can have problems, so i always put a thin coat of high-temperature silicone vacuum grease on threads before I screw in a new bulb.  I use Dow-Corning "High Vacuum Grease." The price ranges from about $20 to $32 for a 150-gram tube, but it will last for several generations.  I also use this grease on outdoor electrical and RF connectors to provide additional water resistance.

OldGeek
User Rank
Iron
Re: LAMP SOCKETS, etal....
OldGeek   4/11/2012 11:42:06 AM
NO RATINGS
Jon, I think you're dead on about the need for an update in socket design. I'm also pretty sure it won't happen any time soon just because of the enormous number of installed sockets. If a good design comes forward that could be easily fitted to existing sockets by using a screw in adapter it would have a much better chance.

Your particular problem is primarily because of the 3-way design. In the standard base, the rivets don't have to remain tight because the spring on the center contact keeps them held against the socket shell. Because the third contact of your socket is solid, the only thing holding the rivet tight is the springiness of the socket shell and that doesn't have enough "give" to be much help. If you can't find a socket with a spring third contact the addition of a screw might be your best shot, especially if you add a spring lock washer.

While a brass socket shell SOUNDS like a good idea, it has one major flaw: all modern light bulbs have an aluminum base. Brass sockets went out of favor soon after bulb bases changed to aluminum, probably because electrolytic corrosion started cementing bulbs into sockets.

Best of luck in your quest for the perfect socket :-)

 

Jon Titus
User Rank
Blogger
How many wires in a box?
Jon Titus   4/11/2012 11:38:36 AM
NO RATINGS
Hi, OLD_CURMUDGEON.  The electrical code specifies a certain size box given the number and gauges of wires in the box. So if you overstuff a box, your work won't pass inspection. Boxes should have their volume clearly marked and a calculation yields the volume needed for the wires.  Fine Homebuilding magazine ran an article that includes an example: http://www.finehomebuilding.com/how-to/articles/more-wires-need-bigger-boxes.aspx.

Dave Palmer
User Rank
Platinum
Re: Lamp socket construction sparks danger.
Dave Palmer   4/11/2012 10:32:27 AM
NO RATINGS
@RNDDUDE: I agree with you; the root cause of the problem in the lamp story seems likely to be galvanic corrosion between the aluminum sleeve and the copper tube.  It doesn't help that copper is at the top of the galvanic series and aluminum is at the bottom.  They just don't play well together.

bob from maine
User Rank
Platinum
Lamp Socket Sparks Danger
bob from maine   4/11/2012 10:23:08 AM
The current path on those sockets is thru the rivet to the aluminum outer sleeve which makes contact with the threads on the bulb. The rivet to wire type of connection is also used in UL approved mechanism's such as electric motor starter circuits that use a printed circuit board. Once any resistance develops, heat follows, with hundred or thousands of cycles, eventually the resistance gets high enough to cause enough heat to carbonize the supporting plastic and restistance increases, etc. etc.. General Electric made a series of hot water circulating pumps used on furnaces from the 50's to at least the 90's and they had a brass rivet holding a crimped wire terminal against the printed circuit board. Once a little oxidation appeared the resistance went up and each time the motor started, a small arc would occur. Eventually this arc would cause the epoxy board to decompose and the contact would become intermittent. It was a real difficult problem to locate and the solution required replacing a $115 motor because the $1.50 circuit board wasn't available. Using this type of termination for components is not all that uncommon, even today.

Page 1/3  >  >>


Partner Zone
Latest Analysis
A new battery design, which replaces lithium with abundant and low-cost elemental sulfur, is still in its nascent stages but shows real promise for giving batteries more energy potential.
PTC will offer a virtual desktop environment for its Creo product design applications, potentially freeing engineers to run them from remote desktops on a variety of operating systems and mobile devices.
The push to achieving more intelligent, integrated manufacturing is putting a strong focus on networking and connectivity as key enabling technologies.
Software maker PTC drew applause and cheers at PTC Live Global 2013 when it announced it will offer a "multi-CAD" strategy early next year.
Now that solar and wind harvesting technologies are a thriving market, researchers are seeking other environmentally related energy sources for which they can create harvesting devices.
More:Blogs|News
Design News Webinar Series
5/30/2013 11:00 a.m. California / 2:00 p.m. New York / 7:00 p.m. London
5/29/2013 11:00 a.m. California / 2:00 p.m. New York / 7:00 p.m. London
6/25/2013 11:00 a.m. California / 2:00 p.m. New York / 7:00 p.m. London
6/27/2013 11:00 a.m. California / 2:00 p.m. New York / 7:00 p.m. London
Blogs from Our Sponsors
From Dell / Intel®
New Paradigms in Design Work
Scott Hamilton, vertical market strategist for Dell Precision workstations, 5/2/2013    5
Early in my career, I worked as a draftsman and remember the days of drawing on vellum with numbered pencils and Mylar with plastic lead. This was a fun experience in the sense that I ...
From Dell / Intel®
Increased Workstation Performance Is as Easy as 'DPPO'
Trey Morton, Dell, 4/25/2013    2
I've been using workstations for more than 10 years and love finding ways to get more performance from my system. With demanding professional applications that require more power each ...
From Dell / Intel®
Taking Some of the Grit out of Manufacturing
Kirsten Billhardt, Manufacturing Industry Marketing Strategist, Dell, 3/26/2013    5
A lasting memory from my first job as an engineer in an auto assembly plant is standing on hard concrete at six in the morning, vending-machine coffee clutched in hand, listening to ...
Quick Poll
The Continuing Education Center offers engineers an entirely new way to get the education they need to formulate next-generation solutions.
Jun 24 - 28, Design Your Own Android App
SEMESTERS: 1  |  2  |  3


DN Radio
Sponsored by
NEXT UPCOMING BROADCAST
For industrial control applications, or even a simple assembly line, that machine can go almost 24/7 without a break. But what happens when the task is a little more complex? That’s where the “smart” machine would come in. The smart machine is one that has some simple (or complex in some cases) processing capability to be able to adapt to changing conditions. Such machines are suited for a host of applications, including automotive, aerospace, defense, medical, computers and electronics, telecommunications, consumer goods, and so on. This radio show will show what’s possible with smart machines, and what tradeoffs need to be made to implement such a solution.
Twitter Feed
Design News Twitter Feed
Like Us on Facebook

Sponsored Content

Technology Marketplace

Datasheets.com Parts Search

185 million searchable parts
(please enter a part number or hit search to begin)
Copyright © 2013 UBM Canon, A UBM company, All rights reserved. Privacy Policy | Terms of Service