William K.
User Rank
Platinum
over riding the 3 speed switch.
William K.   3/28/2012 9:47:42 PM
NO RATINGS
Almost all fans offered to both consumers and many commercial applications do indeed start with the highest speed setting because some of these fans are such junk that they wont start at the low speed setting, although they will run there once spinning. That is because the motor design is marginal and the phase shifting capacitor needed to make the motor run is a cheaply made device, with no capacitance to spare. So to avoid thye stall condition the fastest speed is what comes on first. That is useful because the inferior lubricant on many of these devices does tend to turn sticky and to restrict rotation. So the high speed start is definitely a "CYA" type of design choice.

OldGeek
User Rank
Iron
Re: 3-speed fan motor control
OldGeek   3/28/2012 5:32:20 PM
NO RATINGS
Yes Rob, I think you'll agree that regardless of the sequence of operation, the string would have been sucked into the fan as soon as it was put on "High".

I think OLD_CRUMUDGEON has a good point too. If mounted in a narrow hallway I could see the air velocity being more likely to cause the string to be sucked into the inlet than if mounted in a large room.

Still, for it to happen the string must not have had much if any weight on it!

OldGeek
User Rank
Iron
Re: 3-speed fan motor control
OldGeek   3/28/2012 3:32:13 PM
NO RATINGS
Kenish, you are right! I didn't think about blowers in automobiles!

Yes, DC motors have a steeper torque vs. speed curve than the multi-speed motors used in household fans and are much less prone to sticking. At reduced speed settings, the AC units are essentially constant torque devices where the torque is determined by the current in the windings. The current is controlled by tapped windings in the motor or by externally increasing the impedance. At lower speeds, these motors present an almost pure inductive load that shows little variation with speed. I once replaced the blower motor in a window a/c unit with a higher horsepower "universal" replacement. On turning it on, I found that I had no change between highest and lowest speed settings because the blower didn't load it enough to slow it down!

Rob Spiegel
User Rank
Blogger
Re: 3-speed fan motor control
Rob Spiegel   3/28/2012 3:27:01 PM
NO RATINGS
OldGeek, your last comment may be the most germane when it comes to uncovering the monkey business in this story. The fact that the pull cord could get sucked up into the airstream may be the real design flaw.

kenish
User Rank
Platinum
Re: 3-speed fan motor control
kenish   3/28/2012 2:50:52 PM
NO RATINGS
OldGeek- Same in my house, even an over-the-range microwave with a software-controlled vent hood starts at the highest setting.  OTOH, the blower motor in cars starts with the low setting.  Perhaps because they are DC motors?  I'm an EE but not a motor expert.

uniquity@uniquitypsych.com
User Rank
Gold
Re: Fan switches on the fritz
uniquity@uniquitypsych.com   3/28/2012 2:09:59 PM
NO RATINGS
I have a number of fans in my home.  Four of them are ceiling fans with pull chains.  All of the came with the first pull starting at the highest speed.  One of them had to have the switch replaced, and it ended up with the slowest speed as the first speed.  I have never had a problem with that.  I also have a whole house fan with ceiling louvers.  It is controlled by a wall switch that is temperature sensitive.  You can adjust the switch so the fan will shut off when it cools down the room. 

I have four other ceiling fans that are controlled by rotating wall switches.  They are variable speed, and they all start at the high speed settings.

If the original story had a fan strong enough to pull the chain up, and into the fan, it seems to me the easiest way to solve that problem whould had been to add a heavier weight to the bottom of the pull cord.

williamlweaver
User Rank
Platinum
Re: Fan switches on the fritz
williamlweaver   3/28/2012 1:35:24 PM
NO RATINGS
Yep. The first official Aircraft Carrier. http://en.wikipedia.org/wiki/File:Samuel_Pierpont_Langley_-_Potomac_experiment_1903.jpeg

The Navy's 1st "operational" Aircraft carrier was named in his honor. http://en.wikipedia.org/wiki/USS_Langley_(CV-1)

thrashercharged
User Rank
Iron
Re: Fan switches on the fritz
thrashercharged   3/28/2012 12:57:04 PM
NO RATINGS
Langley launched his machines from an aircraft carrier in the Potomac River... and continuously fished them out from the bottom.

I seriously doubt Langley used an aircraft carrier!  A large boat perhaps!

OldGeek
User Rank
Iron
Re: 3-speed fan motor control
OldGeek   3/28/2012 12:25:22 PM
NO RATINGS
Interesting since EVERY fan in my home (ceiling fans, stand mounted and range exhaust) uses the "Off/High/Medium/Low" sequence.  The range hood is a variable speed unit that the pot is wired to go slower the farther you turn it. All three window air conditioners in my home and garage use that paradigm as well.

In fact, I can't think of a single instance where a fan I've delt with starts out on the lowest setting.

Tecsonics got it right, small motors are notorious for being difficult to start. Starting out at high speed insures that there is enough initial "kick" to get it moving instead of sitting "locked rotor" and burning up. It also gives immediate feedback to the user that the fan is actually "on".

To the original article, that does sound like a "never tested" assembly. The lack of a factory attached weight on the pull cord is a SERIOUS error!

OLD_CURMUDGEON
User Rank
Platinum
"WHOLE HOUSE" fans, etc.
OLD_CURMUDGEON   3/28/2012 12:24:00 PM
I agree with one of the other bloggers.  It seems that some of these comments are confusing ceiling fan operation with whole house central fan operation.  One comment was that the ONLY thing the two devices have in common is the word "fan".

I have installed whole house fans, gable-end attic space fans AND consumer ceiling fans for my own homes, for nontwchnical relatives, and for friends over the years.

The whole house fans that I've installed are designed w/ a dedicated fan-duty squirrel cage motor, in the 1/2 to 1 hp power range.  All of these fans were powered using a separate wall-mounted speed control switch w/ a horsepower rating.

Regarding "systems engineering"...... Having spent several decades doing systems engineering, both from a hardware point of view and a software point of view, I would offer that the manufacturers of these whole house fans really can't do a satisfactory, all-inclusive systems engineering test, since each attic space will have its own unique airflow equation.  Some houses may have a peak vent, in which case the attic air will flow more easily; some houses will be designed w/ a truss system for the roof members, providing considerable flow resistande, others may have corner breaks, etc., while others may have soffet vents.  ALL of these conditions will alter the flow rate of the air through an additionally provided (self-closing) louver device.

In fact, in our current house in FLA, we have a gable end attic fan w/ a gravity/flow operated louver.  It has been in place for close to 20 years, and now it is evident that the rivets holding the louver blades to the frame are wearing, resulting in erratic operation of the louver when the fan is energized.  However, this fan was installed to assist in "cooling" the attic space to aid the living space HVAC unit.  Since the house has recently been re-roofed, and a full-length high-flow (passive) ridge vent installed, we hardly use the fan any more.

<<  <  Page 2/4  >  >>


Partner Zone
Latest Analysis
We see Gadget Freak projects from all walks of life, but many of our most imaginative gadgets are created by budding engineers.
By experimenting with the photovoltaic reaction in solar cells, researchers at MIT have made a breakthrough in energy efficiency that significantly pushes the boundaries of current commercial cells on the market.
Advanced Micro Devices' latest release brings a cloud-based graphics boost, along with unparalleled performance, to the workstation.
In a world that's going green, industrial operations have a problem: Their processes involve materials that are potentially toxic, flammable, corrosive, or reactive. If improperly managed, this can precipitate dangerous health and environmental consequences.
With LEDs dropping in price virtually every year, automakers have begun employing them, not only on luxury vehicles, but on entry-level models, as well.
More:Blogs|News
Design News Webinar Series
5/22/2013 9:00 a.m. California / 12:00 p.m. New York / 5:00 p.m. London
5/15/2013 11:00 a.m. California / 2:00 p.m. New York / 7:00 p.m. London
5/29/2013 11:00 a.m. California / 2:00 p.m. New York / 7:00 p.m. London
5/30/2013 11:00 a.m. California / 2:00 p.m. New York / 7:00 p.m. London
Blogs from Our Sponsors
From Dell / Intel®
New Paradigms in Design Work
Scott Hamilton, vertical market strategist for Dell Precision workstations, 5/2/2013    3
Early in my career, I worked as a draftsman and remember the days of drawing on vellum with numbered pencils and Mylar with plastic lead. This was a fun experience in the sense that I ...
From Dell / Intel®
Increased Workstation Performance Is as Easy as 'DPPO'
Trey Morton, Dell, 4/25/2013    2
I've been using workstations for more than 10 years and love finding ways to get more performance from my system. With demanding professional applications that require more power each ...
From Dell / Intel®
Taking Some of the Grit out of Manufacturing
Kirsten Billhardt, Manufacturing Industry Marketing Strategist, Dell, 3/26/2013    5
A lasting memory from my first job as an engineer in an auto assembly plant is standing on hard concrete at six in the morning, vending-machine coffee clutched in hand, listening to ...
Quick Poll
The Continuing Education Center offers engineers an entirely new way to get the education they need to formulate next-generation solutions.
Jun 10 - 14, Exploring Application-Specific Programmable Logic Devices
SEMESTERS: 1  |  2  |  3


DN Radio
Sponsored by
NEXT UPCOMING BROADCAST
A quick look into the merger of two powerhouse 3D printing OEMs and the new leader in rapid prototyping solutions, Stratasys. The industrial revolution is now led by 3D printing and engineers are given the opportunity to fully maximize their design capabilities, reduce their time-to-market and functionally test prototypes cheaper, faster and easier. Bruce Bradshaw, Director of Marketing in North America, will explore the large product offering and variety of materials that will help CAD designers articulate their product design with actual, physical prototypes. This broadcast will dive deep into technical information including application specific stories from real world customers and their experiences with 3D printing. 3D Printing is
Twitter Feed
Design News Twitter Feed
Like Us on Facebook

Sponsored Content

Technology Marketplace

Datasheets.com Parts Search

185 million searchable parts
(please enter a part number or hit search to begin)
Copyright © 2013 UBM Canon, A UBM company, All rights reserved. Privacy Policy | Terms of Service