six wire technique
vimalkumarp   11/26/2011 10:59:11 AM
NO RATINGS
This is very useful idea for ICT development.

 

William K.
User Rank
Platinum
Six wire technique nulls stray resistance
William K.   11/17/2011 10:51:04 PM
NO RATINGS
A whole bunch of years ago I designed and improved system for checking the fuel injection system s tverify that all 4 of the 1.2 ohm injectors were connected.  I replaced a resistance measuring systemthat had problems with one that used a constant current source. Because the injectors were relatively high power devices I was allowed to run 100Ma through the harness as part of the test. I used a constant current regulated source, and so the connected harness assembly yielded 100 millivolts per ohm, entirely adequate resolution. My application only required four wires to provide the needed accuracy. It worked well and saved our company a lot of money, and it made our customer happy as well. On top of that, it gave us a very short product lead time. 

GotCMRR
User Rank
Iron
Clever technique
GotCMRR   11/16/2011 9:35:28 AM
NO RATINGS
Simple & elegant.  Just watch your OpAmp's feedback polarity.  Your schematic as drawn doesn't work ;)

Beth Stackpole
User Rank
Blogger
Re: More complexity, more work?
Beth Stackpole   11/15/2011 11:05:50 AM
NO RATINGS
Got it. Thanks for clarifying, Jon.

Jon Titus
User Rank
Blogger
Re: More complexity, more work?
Jon Titus   11/15/2011 10:40:22 AM
NO RATINGS
Hi, Beth.

If you have a resistance (A)  in a network of other resistances, Ohm's Law dictates the resistance you would measure directly across resistance A.  To accurately measure resistance A by itself, you either isolate it from the circuit (removing it would do the job) or electrically null the other resistances so no current flows through them.  That's what the 6-wire technique does.  Automatic test equipment (ATE) uses a similar technique to electrically isolate resistances.  By the way, a similar technique would for capacitances, too.

The need to electrically isolate components does require extra test equipment, but the 6-wire technique offers the only practical way to make accurate in-circuit resistance or capacitance measurements.--Jon

Beth Stackpole
User Rank
Blogger
More complexity, more work?
Beth Stackpole   11/15/2011 6:40:16 AM
NO RATINGS
So if I understand it correctly, this six-wire technique works best when there's a network of resistors and you're challenged with measuring the resistance of only one? It also makes sense when measuring resistance with test equipment because of the possible interferences by dirt, grim, etc.? I'm wondering how much more difficult this technique is compared with standard practices?

 

 



Partner Zone
Latest Analysis
BMW has already incorporated more than 10,000 3D-printed parts in the Rolls-Royce Phantom and intends to expand the use of 3D printing in its cars even more in the future. Meanwhile, Daimler has started using additive manufacturing for producing spare parts in Mercedes-Benz Trucks.
Researchers have been developing a number of nano- and micro-scale technologies that can be used for implantable medical technology for the treatment of disease, diagnostics, prevention, and other health-related applications.
SABIC's lightweighting polycarbonate glazing materials have appeared for the first time in a production car: the rear quarter window of Toyota's special edition 86 GRMN sports car, where they're saving 50% of its weight compared to conventional glass.
Take a look at some of the best movies that include self-aware machines.
An engineer in the United Kingdom has found inspiration in nature for the design of bridges that are far stronger and more durable than current designs.
More:Blogs|News
Quick Poll
The Continuing Education Center offers engineers an entirely new way to get the education they need to formulate next-generation solutions.
Jul 11 - 15, Embedded System Design Techniques™ - Debugging Real-time Embedded Software – Hands on
SEMESTERS: 1  |  2  |  3  |  4  |  5  |  6 |  7 | 8 | 9 | 10


Focus on Fundamentals consists of 45-minute on-line classes that cover a host of technologies. You learn without leaving the comfort of your desk. All classes are taught by subject-matter experts and all are archived. So if you can't attend live, attend at your convenience.
Learn More   |   Login   |   Archived Classes
Twitter Feed
Design News Twitter Feed
Like Us on Facebook

Technology Marketplace

Copyright © 2016 UBM Canon, A UBM company, All rights reserved. Privacy Policy | Terms of Service