vimalkumarp
User Rank
Gold
six wire technique
vimalkumarp   11/26/2011 10:59:11 AM
NO RATINGS
This is very useful idea for ICT development.

 

William K.
User Rank
Platinum
Six wire technique nulls stray resistance
William K.   11/17/2011 10:51:04 PM
NO RATINGS
A whole bunch of years ago I designed and improved system for checking the fuel injection system s tverify that all 4 of the 1.2 ohm injectors were connected.  I replaced a resistance measuring systemthat had problems with one that used a constant current source. Because the injectors were relatively high power devices I was allowed to run 100Ma through the harness as part of the test. I used a constant current regulated source, and so the connected harness assembly yielded 100 millivolts per ohm, entirely adequate resolution. My application only required four wires to provide the needed accuracy. It worked well and saved our company a lot of money, and it made our customer happy as well. On top of that, it gave us a very short product lead time. 

GotCMRR
User Rank
Iron
Clever technique
GotCMRR   11/16/2011 9:35:28 AM
NO RATINGS
Simple & elegant.  Just watch your OpAmp's feedback polarity.  Your schematic as drawn doesn't work ;)

Beth Stackpole
User Rank
Blogger
Re: More complexity, more work?
Beth Stackpole   11/15/2011 11:05:50 AM
NO RATINGS
Got it. Thanks for clarifying, Jon.

Jon Titus
User Rank
Blogger
Re: More complexity, more work?
Jon Titus   11/15/2011 10:40:22 AM
NO RATINGS
Hi, Beth.

If you have a resistance (A)  in a network of other resistances, Ohm's Law dictates the resistance you would measure directly across resistance A.  To accurately measure resistance A by itself, you either isolate it from the circuit (removing it would do the job) or electrically null the other resistances so no current flows through them.  That's what the 6-wire technique does.  Automatic test equipment (ATE) uses a similar technique to electrically isolate resistances.  By the way, a similar technique would for capacitances, too.

The need to electrically isolate components does require extra test equipment, but the 6-wire technique offers the only practical way to make accurate in-circuit resistance or capacitance measurements.--Jon

Beth Stackpole
User Rank
Blogger
More complexity, more work?
Beth Stackpole   11/15/2011 6:40:16 AM
NO RATINGS
So if I understand it correctly, this six-wire technique works best when there's a network of resistors and you're challenged with measuring the resistance of only one? It also makes sense when measuring resistance with test equipment because of the possible interferences by dirt, grim, etc.? I'm wondering how much more difficult this technique is compared with standard practices?

 

 



Partner Zone
Latest Analysis
McLaren is one of the biggest names in auto racing. But now it has its eyes on a whole new challenge -- innovating healthcare.
What if algae borne of fertilizer runoff that pollutes rivers and lakes could be harvested and used as biofuel feedstock? What if the leftovers could be recycled into farm soil nutrients, eliminating at least some of the need for artificial fertilizers in the first place? Western Michigan University researchers have a plan.
PTC will stream its LiveWrox IoT conference for free beginning Tuesday, May 5.
Manufacturers of plastic parts recognize the potential of conformal cooling to reduce molding cycle times. Problem is, conformal molds require additive manufacturing (AM), and technologies in that space are still evolving. Costs also can be high, and beyond that, many manufacturing organizations lack the knowledge and expertise needed to apply and incorporate additive technologies into their operations.
Stratasys has announced the winners in its 11th annual Extreme Redesign contest for middle school, high school, and college students around the world in engineering, design, and art or architecture.
More:Blogs|News
Design News Webinar Series
3/31/2015 11:00 a.m. California / 2:00 p.m. New York
2/25/2015 11:00 a.m. California / 2:00 p.m. New York
12/11/2014 8:00 a.m. California / 11:00 a.m. New York
5/7/2015 11:00 a.m. California / 2:00 p.m. New York
Quick Poll
The Continuing Education Center offers engineers an entirely new way to get the education they need to formulate next-generation solutions.
May 4 - 8, Designing Low Power Systems using Battery and Energy Harvesting Energy Sources
SEMESTERS: 1  |  2  |  3  |  4  |  5  |  6 |  7


Focus on Fundamentals consists of 45-minute on-line classes that cover a host of technologies. You learn without leaving the comfort of your desk. All classes are taught by subject-matter experts and all are archived. So if you can't attend live, attend at your convenience.
Last Archived Class
Sponsored by Proto Labs
Learn More   |   Login   |   Archived Classes
Twitter Feed
Design News Twitter Feed
Like Us on Facebook

Sponsored Content

Technology Marketplace

Copyright © 2015 UBM Canon, A UBM company, All rights reserved. Privacy Policy | Terms of Service