HOME  |  NEWS  |  BLOGS  |  MESSAGES  |  FEATURES  |  VIDEOS  |  WEBINARS  |  INDUSTRIES  |  FOCUS ON FUNDAMENTALS
REGISTER   |   LOGIN   |   HELP
<<  <  Page 2/3  >  >>
MYRONB
User Rank
Gold
Re:Countertop sSocks
MYRONB   9/6/2011 12:45:25 PM
NO RATINGS
I'm having a hard time understanding how the metal band on your countertop could act like a secondary winding driven by the primary in the base of your toothbrush holder/charger.  I have such a toothbrush and the magnetic flux in the base is so feeble that moving the tooth brush a fraction of an inch from the base stops the charging effect in the toothbrush.  I just can't see any way this weak field could induce a current flow in the counter trim strip.  Furthermore, the trim strip is essentially a one-turn secondary.  if it's a continuous strip, it's a shorted one-turn secondary with zero volts output, or if not a closed loop, and being one turn only, I believe its induced voltage would be so low as to be imperceptable.

There are other possible causes of the shock that was felt.  I would look to see if the whole bathroom lighting and accessory outlets have been wired correctly, and that the ground and hot supply leads weren't mixed up resulting in electrically hot (supposedly) grounded surfaces.

I'm sure there are other cases like this, but I clearly recall a situation in London, England where an electrician mixed the hot and ground leads to a bathroom outlet that resulted in fatally shocking the user of an electric shaver. 

Myron J. Boyajian

MLM-TS
User Rank
Iron
Info missing
MLM-TS   9/6/2011 12:33:55 PM
NO RATINGS
Between what two points are you measuring 30 - 50V?  You can't get a shock on a closed loop with a circulating current, (see works of Kirchhoff & Lenz), so I assume you measured between the trim and ground.  If so, simply patch an incandescent bulb -any wattage- between the same two points and measure again.  I wager that the bulb will not light, and the voltage will drop to a few dozen mV, because you have a small capacitive coupling from some energized conductor to the floating trim.   Maybe the toothbrush charger or even a hair-dryer power cord.  If so, just ground the trim and fuggedaboutit.  You can feel currents too small to trip a GFCI, and it's not necessarily dangerous - just startling.

David12345
User Rank
Platinum
Re: Protection
David12345   9/6/2011 12:22:49 PM
NO RATINGS
Two Comments:

1) I have seen these metal edges on older counters in kitchens or bathrooms to provide a dressed-up trim on either formica or tile counters.  This trim was primarily eliminated when granite, CorianTM, and laminated edges were developed and esthetically preferred.

2) I was corrected years ago, by a former Navy Officer, that "Duct" tape is properly called "Duck" tape as it was developed in WW II for the Navy primarily to use in Ships, and Submarines over asbestos pipe insulation.  Hence, the reason for the Navy Gray color. It obviously found many other uses including sealing of sheetmetal ductwork.

Dangela
User Rank
Bronze
GFI
Dangela   9/6/2011 9:48:02 AM
NO RATINGS
Rob,

Was the base plugged into a GFI outlet? That would have caught any leakage.

jmiller
User Rank
Platinum
'nother question.
jmiller   9/5/2011 11:42:19 PM
NO RATINGS
So was the countertop energized all the time or only when the toothbrush was being charged.  Also, was the change generated from the energy going from the base to the toothbrush?  How did you rule out the possibility that the base was directly influencing the trim?

BobGroh
User Rank
Platinum
Re: Old is new
BobGroh   9/2/2011 2:21:51 PM
NO RATINGS
Mr. Wolfe - your duct tape comment got a big chuckle out of yours truly!  Somebody is having a good day!

Rob Spiegel
User Rank
Blogger
RE: Shocking Bathroom Countertop
Rob Spiegel   9/2/2011 12:22:51 PM
NO RATINGS
Hi Bob,

I think your story would make a good Sherlock Ohms posting. If you;re interested, please flesh it out with a tad more detail and send it along to: rob.spiegel@ubm.com

I hope to see it.

BobGroh
User Rank
Platinum
RE: Shocking Bathroom Countertop
BobGroh   9/2/2011 11:42:13 AM
NO RATINGS
I totally agree with 'armorris' on this - the problem could not (well, let me rephrase that a bit - it is highly improbable) be due to the toothbrush charger coupling to the metal rim.  There is a leakage path someplace and I would seriously suggest some more aggressive work to figure out what it is.  Having something put 30 to 50 V out there is NOT a good thing.

I had a somewhat similar situation a good many years ago. I had added a workbench in a bedroom which was located in the basement (the bedroom and the interior wiring had been added by the previous owner) and, when the workbench's outlets were plugged into the wall outlet, I was getting a 'tingle' when I held a grounded tool.  Not good. 

I tore into the electrical system downstairs and finally found the culprit - on one of the metal boxes on a homemade extension cord, the screw on the cord clamp was too long and was contacting the hot wire in the cord.  This essentially put 120VAC on the ground - the connection was not solid enough for a 'solid' short but did manage to drag the grounds up to about 50 V above earth ground.  A very solid 'tingle' indeed.

My recommendation: find the 'real' problem.

armorris
User Rank
Platinum
Re: Old is new
armorris   9/2/2011 11:20:26 AM
NO RATINGS
I'm a retired Electrical Engineer. It is not possible for the coil in the toothbrush charger to induce 30-50 volts into the metal trim on the countertop. That kind of voltage can only come from leakage. If removing the toothbrush charger fixed the problem, then insulation leakage in the charger base is the problem and water has conducted the current to the metal trim. The coupling between the primary coil in the charger (60Hz to maybe 75KHz) is far too small to induce such voltage into the trim on the countertop.

Beth Stackpole
User Rank
Blogger
Re: Protection
Beth Stackpole   9/2/2011 9:22:03 AM
NO RATINGS
Funny that the charge didn't happen immediately after using the electric toothbrush, or did it? I guess you can count me in with the others who would have opted to replace the counter top because of many reasons, including the charge. But the fix definitely would not have been done with duct tape--white color or otherwise!

<<  <  Page 2/3  >  >>


Partner Zone
Latest Analysis
Eric Chesak created a sensor that can detect clouds, and it can also measure different sources of radiation.
Festo's BionicKangaroo combines pneumatic and electrical drive technology, plus very precise controls and condition monitoring. Like a real kangaroo, the BionicKangaroo robot harvests the kinetic energy of each takeoff and immediately uses it to power the next jump.
Practicing engineers have not heeded Yoda's words.
Design News and Digi-Key presents: Creating & Testing Your First RTOS Application Using MQX, a crash course that will look at defining a project, selecting a target processor, blocking code, defining tasks, completing code, and debugging.
Rockwell Automation recently unveiled a new safety relay that can be configured and integrated through existing software to program safety logic in devices.
More:Blogs|News
Design News Webinar Series
3/27/2014 11:00 a.m. California / 2:00 p.m. New York / 7:00 p.m. London
2/27/2014 11:00 a.m. California / 2:00 p.m. New York / 7:00 p.m. London
12/18/2013 Available On Demand
11/20/2013 Available On Demand
Quick Poll
The Continuing Education Center offers engineers an entirely new way to get the education they need to formulate next-generation solutions.
Apr 21 - 25, Creating & Testing Your First RTOS Application Using MQX
SEMESTERS: 1  |  2  |  3  |  4  |  5


Focus on Fundamentals consists of 45-minute on-line classes that cover a host of technologies. You learn without leaving the comfort of your desk. All classes are taught by subject-matter experts and all are archived. So if you can't attend live, attend at your convenience.
Next Class: April 29 - Day 1
Sponsored by maxon precision motors
Learn More   |   Login   |   Archived Classes
Twitter Feed
Design News Twitter Feed
Like Us on Facebook

Sponsored Content

Technology Marketplace

Datasheets.com Parts Search

185 million searchable parts
(please enter a part number or hit search to begin)
Copyright © 2014 UBM Canon, A UBM company, All rights reserved. Privacy Policy | Terms of Service