Between what two points are you measuring 30 - 50V? You can't get a shock on a closed loop with a circulating current, (see works of Kirchhoff & Lenz), so I assume you measured between the trim and ground. If so, simply patch an incandescent bulb -any wattage- between the same two points and measure again. I wager that the bulb will not light, and the voltage will drop to a few dozen mV, because you have a small capacitive coupling from some energized conductor to the floating trim. Maybe the toothbrush charger or even a hair-dryer power cord. If so, just ground the trim and fuggedaboutit. You can feel currents too small to trip a GFCI, and it's not necessarily dangerous - just startling.
1) I have seen these metal edges on older counters in kitchens or bathrooms to provide a dressed-up trim on either formica or tile counters. This trim was primarily eliminated when granite, CorianTM, and laminated edges were developed and esthetically preferred.
2) I was corrected years ago, by a former Navy Officer, that "Duct" tape is properly called "Duck" tape as it was developed in WW II for the Navy primarily to use in Ships, and Submarines over asbestos pipe insulation. Hence, the reason for the Navy Gray color. It obviously found many other uses including sealing of sheetmetal ductwork.
So was the countertop energized all the time or only when the toothbrush was being charged. Also, was the change generated from the energy going from the base to the toothbrush? How did you rule out the possibility that the base was directly influencing the trim?
I think your story would make a good Sherlock Ohms posting. If you;re interested, please flesh it out with a tad more detail and send it along to: rob.spiegel@ubm.com
I totally agree with 'armorris' on this - the problem could not (well, let me rephrase that a bit - it is highly improbable) be due to the toothbrush charger coupling to the metal rim. There is a leakage path someplace and I would seriously suggest some more aggressive work to figure out what it is. Having something put 30 to 50 V out there is NOT a good thing.
I had a somewhat similar situation a good many years ago. I had added a workbench in a bedroom which was located in the basement (the bedroom and the interior wiring had been added by the previous owner) and, when the workbench's outlets were plugged into the wall outlet, I was getting a 'tingle' when I held a grounded tool. Not good.
I tore into the electrical system downstairs and finally found the culprit - on one of the metal boxes on a homemade extension cord, the screw on the cord clamp was too long and was contacting the hot wire in the cord. This essentially put 120VAC on the ground - the connection was not solid enough for a 'solid' short but did manage to drag the grounds up to about 50 V above earth ground. A very solid 'tingle' indeed.
I'm a retired Electrical Engineer. It is not possible for the coil in the toothbrush charger to induce 30-50 volts into the metal trim on the countertop. That kind of voltage can only come from leakage. If removing the toothbrush charger fixed the problem, then insulation leakage in the charger base is the problem and water has conducted the current to the metal trim. The coupling between the primary coil in the charger (60Hz to maybe 75KHz) is far too small to induce such voltage into the trim on the countertop.
Funny that the charge didn't happen immediately after using the electric toothbrush, or did it? I guess you can count me in with the others who would have opted to replace the counter top because of many reasons, including the charge. But the fix definitely would not have been done with duct tape--white color or otherwise!
I wonder if the purpose of the metal trim was to prevent damage to the edge of the countertop--something like the metal strip on drywall corners. Possibly the countertop was made of something less durable than the materials used today.
Using almost 200 light-emitting diodes in the front and back of the new 2014 CTS, Cadillac designers are showing how LEDs can change the character of a vehicle.
We looked at a number of sources to determine this year's greenest cars, from KBB to automotive trade magazines to environmental organizations. These 14 cars emerged as being great at either stretching fuel or reducing carbon footprint.
From Dell / Intel® New Paradigms in Design Work Scott Hamilton, vertical market strategist for Dell Precision workstations, 5/2/2013 3
Early in my career, I worked as a draftsman and remember the days of drawing on vellum with numbered pencils and Mylar with plastic lead. This was a fun experience in the sense that I ...
I've been using workstations for more than 10 years and love finding ways to get more performance from my system. With demanding professional applications that require more power each ...
A lasting memory from my first job as an engineer in an auto assembly plant is standing on hard concrete at six in the morning, vending-machine coffee clutched in hand, listening to ...
A quick look into the merger of two powerhouse 3D printing OEMs and the new leader in rapid prototyping solutions, Stratasys. The industrial revolution is now led by 3D printing and engineers are given the opportunity to fully maximize their design capabilities, reduce their time-to-market and functionally test prototypes cheaper, faster and easier. Bruce Bradshaw, Director of Marketing in North America, will explore the large product offering and variety of materials that will help CAD designers articulate their product design with actual, physical prototypes. This broadcast will dive deep into technical information including application specific stories from real world customers and their experiences with 3D printing. 3D Printing is
To save this item to your list of favorite Design News content so you can find it later in your Profile page, click the "Save It" button next to the item.
If you found this interesting or useful, please use the links to the services below to share it with other readers. You will need a free account with each service to share an item via that service.