HOME  |  NEWS  |  BLOGS  |  MESSAGES  |  FEATURES  |  VIDEOS  |  WEBINARS  |  RESOURCE CENTER  |  INDUSTRIES
REGISTER   |   LOGIN   |   HELP
Page 1/2  >  >>
pedalcommuter
User Rank
Iron
Re: Buried receptacle
pedalcommuter   9/8/2011 5:01:54 PM
NO RATINGS
It reminds me of a buried receptacle I had to deal with as a teenager.

I had installed it in a frame addition to the customer's trailer on Lake Norman, NC.  Days later, he called my father and said that he had paneled the room and the receptacle wasn't there.  My father looked at me sternly and informed me of this.  I told him that the customer must have been drunk when he did the paneling - how else could he miss the box sticking out a quarter-inch from the studs?  My dad just told me to go fix it.

I got on-site and could see the bulge in the wall where the receptacle was hiding.  The only problem was that it was "hot" and the breaker box was in the trailer, which was locked.  My perenially inebriated assistant still didn't understand that it was simply a matter of judiciously cutting the paneling to reveal the receptacle and then screwing on the cover plate.  He looked at the concrete floor and said, "Gonna be mighty hard pulling the wire through that concrete floor!"

I took a keyhole saw and bumped it into the paneling where I guessed was the edge of the box.  As luck would have it, it went into the "hot" hole in the receptacle and sent me flying!  My assistant exclaimed, "Told you gonna be hard pulling that wire through that concrete floor!"

Ten minutes later, the job was done.  A month later, I was off to MIT to study electrical engineering.

William K.
User Rank
Platinum
The Case of the Buried Electrical Box Subject
William K.   8/23/2011 10:42:42 AM
NO RATINGS
The reason the signal was stronger at the box is that the box served as additional radiating surface, ( a bigger antenna), which is why the signal was stronger. This would be the case even if the wire was simply cut off and coiled up in the box. The other reason that it worked in this instance is that the box was at the end of the wire.

Tom Shed
User Rank
Iron
Re: The buried electrical box
Tom Shed   8/22/2011 6:21:15 PM
NO RATINGS
...and, the electrical wiring did not meeth the NEC.  Both the electrical and drywall contractors were in over their heads.  

BudM
User Rank
Silver
Re: Cool post.
BudM   8/22/2011 11:46:58 AM
NO RATINGS
The old trick means using transistor radio.

BudM
User Rank
Silver
Re: Cool post.
BudM   8/22/2011 11:27:20 AM
NO RATINGS
This is an old trick used by alot of old tech like me. I use it for locating bad connection in the breaker panel, bad switches, loose connections, etc.

herbissimus
User Rank
Silver
Re: Cool post.
herbissimus   8/22/2011 11:16:25 AM
NO RATINGS
chewing gum foil = plug (edison ) fuse repair kit

one layer = 15 amps

2 layers = 30 amps

3 layers = don't go there !

herbissimus
User Rank
Silver
Re: But But
herbissimus   8/22/2011 11:09:16 AM
NO RATINGS
in the old days we would just roll all the wires into the box, but later the electrical code required that for the rough-in to be complete the wires would be connected as they would be when the installation was complete except for the wiring device (outlet), so the hash would propagate from box to box, no problem. also a set of plans could locate the box to within a few feet, then use the transistor radio from there. the box location would usually give off a stonger signal due to the ball of wire in the box.

donevol
User Rank
Iron
Re: But But
donevol   8/22/2011 10:41:40 AM
NO RATINGS
Most likely the direction or quantity of feeder lines changes at a junction box. Another option is that the electrical bos is/was metal, acting as a shield to reduce the noise radiation.

j-allen
User Rank
Platinum
Re: But But
j-allen   8/22/2011 9:27:01 AM
NO RATINGS
It is clever to use a portable radio with a ferrite loop antenna to detect the brush noise, but I agree the signal would not be significantly stronger at the box than along the wiring leading to it.  Perhaps once this method had located the general area, one might use a metal detector, an RF based stud-finder, or even a pocket compass to find the exact spot.  All this assumes that the electrician was not so sloppy as the dry-waller and used a traditional steel box. 

William K.
User Rank
Platinum
The buried electrical box
William K.   8/22/2011 9:15:23 AM
NO RATINGS
I agree with Beth, but Bob is right to question why the box was so far back that it could have drywall run right over it and not need a cutout. That is just plain poor work quality. Having done a whole lot of reworks of other peoples installations, it is clear that lazy construction practices make everybody else's work more difficult for many years to follow. 

Of course, I am aware that if the box needs a cutout then the sheetrock installer needs to do more work, which does make the whole job take longer, but if the electrician needs to fight with a box that is set back to far, that also takes more time as well.

Page 1/2  >  >>


Partner Zone
Latest Analysis
For 3D printing to make the jump from rapid prototyping to manufacturing, engineers will need to find easier ways to move products from their CAD screens to their printers.
Gigabit and PoE are two networking technologies moving ahead in tandem as industrial users power remote Ethernet devices such as IP security cameras at 1,000 Mbps over existing CAT5 cable.
When an artificial product is manufactured to match its real-world version, some qualities should be reviewed and discarded.
Joining porous metal to mating components for medical and life sciences applications can be accomplished in a variety of ways.
New versions of BASF's Ecovio line are both compostable and designed for either injection molding or thermoforming. These combinations are becoming more common for the single-use bioplastics used in food service and food packaging applications, but are still not widely available.
More:Blogs|News
Design News Webinar Series
5/30/2013 11:00 a.m. California / 2:00 p.m. New York / 7:00 p.m. London
5/29/2013 11:00 a.m. California / 2:00 p.m. New York / 7:00 p.m. London
6/25/2013 11:00 a.m. California / 2:00 p.m. New York / 7:00 p.m. London
6/27/2013 11:00 a.m. California / 2:00 p.m. New York / 7:00 p.m. London
Blogs from Our Sponsors
From Dell / Intel®
New Paradigms in Design Work
Scott Hamilton, vertical market strategist for Dell Precision workstations, 5/2/2013    5
Early in my career, I worked as a draftsman and remember the days of drawing on vellum with numbered pencils and Mylar with plastic lead. This was a fun experience in the sense that I ...
From Dell / Intel®
Increased Workstation Performance Is as Easy as 'DPPO'
Trey Morton, Dell, 4/25/2013    2
I've been using workstations for more than 10 years and love finding ways to get more performance from my system. With demanding professional applications that require more power each ...
From Dell / Intel®
Taking Some of the Grit out of Manufacturing
Kirsten Billhardt, Manufacturing Industry Marketing Strategist, Dell, 3/26/2013    5
A lasting memory from my first job as an engineer in an auto assembly plant is standing on hard concrete at six in the morning, vending-machine coffee clutched in hand, listening to ...
Quick Poll
The Continuing Education Center offers engineers an entirely new way to get the education they need to formulate next-generation solutions.
Jun 24 - 28, Design Your Own Android App
SEMESTERS: 1  |  2  |  3


DN Radio
Sponsored by
NEXT UPCOMING BROADCAST
For industrial control applications, or even a simple assembly line, that machine can go almost 24/7 without a break. But what happens when the task is a little more complex? That’s where the “smart” machine would come in. The smart machine is one that has some simple (or complex in some cases) processing capability to be able to adapt to changing conditions. Such machines are suited for a host of applications, including automotive, aerospace, defense, medical, computers and electronics, telecommunications, consumer goods, and so on. This radio show will show what’s possible with smart machines, and what tradeoffs need to be made to implement such a solution.
Twitter Feed
Design News Twitter Feed
Like Us on Facebook

Sponsored Content

Technology Marketplace

Datasheets.com Parts Search

185 million searchable parts
(please enter a part number or hit search to begin)
Copyright © 2013 UBM Canon, A UBM company, All rights reserved. Privacy Policy | Terms of Service