Rob Spiegel
User Rank
Blogger
Efficiency always
Rob Spiegel   10/11/2013 10:48:49 AM
NO RATINGS
This is just one more example of increased efficiency in power supplier. It will be interesting to see the cumulative effect of efficiency gains in so many areas.

j-allen
User Rank
Gold
Power supply efficiency
j-allen   10/14/2013 9:25:15 AM
NO RATINGS
If you need a wattmeter, an excellent and economical choice is the Weston 310 series.  These are the "Lab Standard" instruments in the mahogany cases rated at 1/4% accruacy.  Since they are electrodynamometers they measure true watts and they have no permanent magnets that can change strength over time.  You can check their calibration with DC using an accurate voltmeter and ammeter on the potential and current terminals, respectively, but it is best to flip polarity to check both ways.  

These instruments were very expensive when new (>$1000), but are now available quite cheaply on the used market.  And they are real works of art. 

ChuckMahoney
User Rank
Gold
non linear loads
ChuckMahoney   10/14/2013 11:06:32 AM
NO RATINGS
This article seems to ignore the fact that most (those without active PFC) AC-DC power supplies are non-linear loads, and therefore the traditional concept of power factor doesn't apply. Current drawn by a typical SMPS (like a computer power supply) is in phase with the voltage since the bulk filter caps charge at the peak of the voltage waveform. The resultant waveform is severly distorted however. This is not the case if the SMPS uses active power factor correction. 

For non-linear loads, make sure to use a wattmeter designed to measure distorted waveforms. You can check for distortion by measuring the Crest Factor of the waveform using a DMM that has a peak capture mode and can measure true RMS. A pure sinewave will have a crest factor (Peak/RMS ratio) of 1.414. Any variation greater or lower indicates distortion. Typical SMPS current draw waveforms will have a very high crest factor, generally around 5. This indicates the typical "peaky" current waveform when caps charge at the peak of the voltage waveform. [voltage waveform distortion - especially in SMPS - tend to have crest factors less than 1.414 due to voltage flattopping]

An SMPS with active PFC will have sinusoidal (well, very nearly sinusoidal) voltage and current waveforms, and they will be in phase so input power is simply VrmsxIrms.

William K.
User Rank
Platinum
Considering the noise, as well
William K.   10/14/2013 8:33:36 PM
NO RATINGS
This is an interesting and useful posting. But sometimes the readings from a noisy supply will be inacurate because of the noise on top of the DC output, and possibly on top of the input as well. An easy solution is to add filtering and read the voltage outside the filters. Usually the output voltage will be different with the noise filtered out, either higher or lower. Likewise the current, although it will usually be lower. This does reflect that noisy supplies are not as good as quieter ones.

Partner Zone
Latest Analysis
In this TED presentation, Wayne Cotter, a computer engineer turned standup comic, explains why engineers are natural comedians.
IBM's new SyNAPSE chip makes it possible for computers to both memorize and compute simultaneously.
The “Space Kid,” 11, will be one of the first civilians to have his design manufactured in space by NASA, thanks to the City X Project, which inspires kids to think about new 3D-printed inventions that could be useful for humans living in space.
We searched far and wide for the top employers for engineers. These companies were ranked by engineering professionals, engineering students, and engineering instructors and professors. Does your employer make the grade?
Sherlock Ohms highlights stories told by engineers who have used their deductive reasoning and technical prowess to troubleshoot and solve the most perplexing engineering mysteries.
More:Blogs|News
Design News Webinar Series
9/10/2014 11:00 a.m. California / 2:00 p.m. New York
7/23/2014 11:00 a.m. California / 2:00 p.m. New York
7/17/2014 11:00 a.m. California / 2:00 p.m. New York
6/25/2014 11:00 a.m. California / 2:00 p.m. New York
Quick Poll
The Continuing Education Center offers engineers an entirely new way to get the education they need to formulate next-generation solutions.
Sep 22 - 26, MCU Software Development – A Step-by-Step Guide (Using a Real Eval Board)
SEMESTERS: 1  |  2  |  3  |  4  |  5  |  6


Focus on Fundamentals consists of 45-minute on-line classes that cover a host of technologies. You learn without leaving the comfort of your desk. All classes are taught by subject-matter experts and all are archived. So if you can't attend live, attend at your convenience.
Next Class: September 30 - October 2
Sponsored by Altera
Learn More   |   Login   |   Archived Classes
Twitter Feed
Design News Twitter Feed
Like Us on Facebook

Sponsored Content

Technology Marketplace

Copyright © 2014 UBM Canon, A UBM company, All rights reserved. Privacy Policy | Terms of Service