Ground Lift
tekochip   9/30/2013 11:14:31 AM
NO RATINGS
In audio, nearly every Direct Box I've ever seen has included a ground lift switch, but on stage it's nearly impossible to get clean power, and I always carried a ground lift adapter for my amp power too.

L. West
User Rank
Iron
cable shield grounding
L. West   9/30/2013 12:52:38 AM
NO RATINGS
The myth of actually shielding with the "shield" grounded at one end only (SPG) has spread throughout the EE design community.  Pseudo-technical argument instills fear of ground loops formed by cable shields grounded at both ends.  See Analog Devices, Analog Dialog 17-1, 1983, for one of the most asinine drawn out of rationales.  The ultimate insanity is when coaxial signal line shields are grounded at one end only.

A cable shield grounded at one end (SPG) behaves like a low pass filter to magnetic fields and a high pass filter to electric fieldsA shield it is not.  The SPG shield actually amplifies EMI at the ¼-wave resonance of the shield with Q ≤ 10.

In fifty years' experience, this author has trouble-shot too many failed systems where the coax signal line shields were left open at one end.  Grounding the coax shield to the line driver and receiver signal return pins with no break in continuity in between killed the noise problem every time.

Two points: (1) A shield installed for shieldingpurposes only must be grounded at both ends preferably to the box connectors; (2) A coax signal line uses the shield for signal return therefore must be grounded to the line driver and receiver signal ground/common pins with no breaks in continuity.  If there is an EMI noise problem with this, the cable should be replaced with a triaxial cable with the outer shield grounded to chassis at both ends or a twinax.

There is a real problem grounding any conductor including shields between two units operating off of two power mains in or between buildings.  Ground potential differences can be kilovolts.  Ethernet has common mode in-line isolation rated at 1.5kV rms per IEEE 802.3.  The shield is not the issue; engineers' knowledge of ground potentials, isolation, and shielding is the issue.  Floating one end of the shield only makes the problem worse.  Isolation units can be inserted to solve most problems.  Fiber optics solves the most difficult problems

With respect to the ground loop induced noise, the ratio of the induced load current to the current in the shield ground loop is Iload/Ignd loop = Z'T·l/2·Zload, exactly what a shield with transfer impedance, Z'T·l, is supposed to do, reduce the induced current below the current on the shield.  The ratio of the induced load voltage to what it would be without the shield in a magnetic field, ω·B·A, is Vload/ω·B·A = Z'T·l/(Z'T·l+ Zgnd) which boils down to L'T/L'gnd.  The shield's transfer inductance, L'T, ranges from 200pH/m to 1nH/m, over an order of magnitude lower than any external cable inductance, L'cable ≈ 200-400nH/m in the shield-ground loop (shielded cable ~3" off of the groundplane). [L'cable = (μ/2·π)·ln(h/2·r)]  Without the shield or with the shield floating at one end, the loads are in the ground loop and are excited directly.  The grounded shield only reduces the induced noise.

Now to the real problems with coax signal lines properly grounded at both ends: unless they are routed close to a structure/chassis ground/cable tray, they emit and receive more EMI than we like, particularly in the broadband mode.  Floating one end of the shield makes it worse.  Routing cables along grounded cable trays helps reduce radiated EMI problems.  If noise problems persist with coax signal lines, they should be replaced with triax or a twinax.

Cable shields should be grounded to the boxes their wires are connected.  No separate connections should be made to the telecommunications grounding busbar (TGB) or telecommunications main grounding busbar (TMGB).  "Grounding" is a misnomer here when we really mean ensure the continuity of the box shields through the cable shield.  ANSI-J-STD-607-A-2002 guides box grounding. 

When shielding cables connected to floating loads like sensors, ground the shield to the sensor case.

Bottom line: Disassociate ground loops from cable shielding.  It is a false argument devoid of correct physics and engineering of shielding and of ground loops, themselves.  If a cable shield doesn't form a ground loop, it is not a shield!!  Ground loop problems and high ground potentials need to be solved by other means like isolation.  Ground loops involve signal and power return connections.

Partner Zone
Latest Analysis
Former DARPA official and Google executive Dr. Kaigham Gabriel believes sensor companies think too much like suppliers and need to bring their products closer to the consumer.
One way to keep a Formula One racing team moving at breakneck speed in the pit and at the test facility is to bring CAD drawings of the racing vehicleís parts down to the test facility and even out to the track.
Most of us would just as soon step on a cockroach rather than study it, but thatís just what researchers at UC Berkeley did in the pursuit of building small, nimble robots suitable for disaster-recovery and search-and-rescue missions.
Engineers at Festo were inspired by how a caterpillar builds its cocoon when designing its new 3D Cocooner printer.
Design engineers need to prepare for a future in which their electronic products will use not just one or two, but possibly many user interfaces that involve touch, vision, gestures, and even eye movements.
More:Blogs|News
Quick Poll
The Continuing Education Center offers engineers an entirely new way to get the education they need to formulate next-generation solutions.
SEMESTERS: 1  |  2  |  3  |  4  |  5  |  6 |  7 | 8 | 9


Focus on Fundamentals consists of 45-minute on-line classes that cover a host of technologies. You learn without leaving the comfort of your desk. All classes are taught by subject-matter experts and all are archived. So if you can't attend live, attend at your convenience.
Next Course June 28-30:
Sponsored by Proto Labs
Learn More   |   Login   |   Archived Classes
Twitter Feed
Design News Twitter Feed
Like Us on Facebook

Technology Marketplace

Copyright © 2016 UBM Canon, A UBM company, All rights reserved. Privacy Policy | Terms of Service