tekochip
User Rank
Platinum
Ground Lift
tekochip   9/30/2013 11:14:31 AM
NO RATINGS
In audio, nearly every Direct Box I've ever seen has included a ground lift switch, but on stage it's nearly impossible to get clean power, and I always carried a ground lift adapter for my amp power too.

L. West
User Rank
Iron
cable shield grounding
L. West   9/30/2013 12:52:38 AM
NO RATINGS
The myth of actually shielding with the "shield" grounded at one end only (SPG) has spread throughout the EE design community.  Pseudo-technical argument instills fear of ground loops formed by cable shields grounded at both ends.  See Analog Devices, Analog Dialog 17-1, 1983, for one of the most asinine drawn out of rationales.  The ultimate insanity is when coaxial signal line shields are grounded at one end only.

A cable shield grounded at one end (SPG) behaves like a low pass filter to magnetic fields and a high pass filter to electric fieldsA shield it is not.  The SPG shield actually amplifies EMI at the ¼-wave resonance of the shield with Q ≤ 10.

In fifty years' experience, this author has trouble-shot too many failed systems where the coax signal line shields were left open at one end.  Grounding the coax shield to the line driver and receiver signal return pins with no break in continuity in between killed the noise problem every time.

Two points: (1) A shield installed for shieldingpurposes only must be grounded at both ends preferably to the box connectors; (2) A coax signal line uses the shield for signal return therefore must be grounded to the line driver and receiver signal ground/common pins with no breaks in continuity.  If there is an EMI noise problem with this, the cable should be replaced with a triaxial cable with the outer shield grounded to chassis at both ends or a twinax.

There is a real problem grounding any conductor including shields between two units operating off of two power mains in or between buildings.  Ground potential differences can be kilovolts.  Ethernet has common mode in-line isolation rated at 1.5kV rms per IEEE 802.3.  The shield is not the issue; engineers' knowledge of ground potentials, isolation, and shielding is the issue.  Floating one end of the shield only makes the problem worse.  Isolation units can be inserted to solve most problems.  Fiber optics solves the most difficult problems

With respect to the ground loop induced noise, the ratio of the induced load current to the current in the shield ground loop is Iload/Ignd loop = Z'T·l/2·Zload, exactly what a shield with transfer impedance, Z'T·l, is supposed to do, reduce the induced current below the current on the shield.  The ratio of the induced load voltage to what it would be without the shield in a magnetic field, ω·B·A, is Vload/ω·B·A = Z'T·l/(Z'T·l+ Zgnd) which boils down to L'T/L'gnd.  The shield's transfer inductance, L'T, ranges from 200pH/m to 1nH/m, over an order of magnitude lower than any external cable inductance, L'cable ≈ 200-400nH/m in the shield-ground loop (shielded cable ~3" off of the groundplane). [L'cable = (μ/2·π)·ln(h/2·r)]  Without the shield or with the shield floating at one end, the loads are in the ground loop and are excited directly.  The grounded shield only reduces the induced noise.

Now to the real problems with coax signal lines properly grounded at both ends: unless they are routed close to a structure/chassis ground/cable tray, they emit and receive more EMI than we like, particularly in the broadband mode.  Floating one end of the shield makes it worse.  Routing cables along grounded cable trays helps reduce radiated EMI problems.  If noise problems persist with coax signal lines, they should be replaced with triax or a twinax.

Cable shields should be grounded to the boxes their wires are connected.  No separate connections should be made to the telecommunications grounding busbar (TGB) or telecommunications main grounding busbar (TMGB).  "Grounding" is a misnomer here when we really mean ensure the continuity of the box shields through the cable shield.  ANSI-J-STD-607-A-2002 guides box grounding. 

When shielding cables connected to floating loads like sensors, ground the shield to the sensor case.

Bottom line: Disassociate ground loops from cable shielding.  It is a false argument devoid of correct physics and engineering of shielding and of ground loops, themselves.  If a cable shield doesn't form a ground loop, it is not a shield!!  Ground loop problems and high ground potentials need to be solved by other means like isolation.  Ground loops involve signal and power return connections.

Partner Zone
Latest Analysis
A Frost & Sullivan study finds that increased cyber attacks are prompting a flurry of innovative protection tools.
Devices and interconnected systems are finding a foothold not only in our homes but in mainstream organizations. Here are three tips to mitigate the risk.
What makes this movie stand out from the typical high school sports story is that the teenagers are undocumented immigrants, and the big game is a NASA-sponsored marine robotics competition. Like many other Hollywood movies, however, Spare Parts only tells part of the story. What the film shows -- and doesn’t show -- raises important issues affecting STEM education in the US.
Instead of sifting through huge amounts of technical data looking for answers to assembly problems, engineers can now benefit from 3M's new initiative -- 3M Assembly Solutions. The company has organized its wealth of adhesive and tape solutions into six typical application areas, making it easier to find the best products to solve their real-world assembly and bonding problems.
Load dump occurs when a discharged battery is disconnected while the alternator is generating current and other loads remain on the alternator circuit. If left alone, the electrical spikes and transients will be transmitted along the power line, leading to malfunctions in individual electronics/sensors or permanent damage to the vehicle’s electronic system. Bottom line: An uncontrolled load dump threatens the overall safety and reliability of the vehicle.
More:Blogs|News
Design News Webinar Series
2/25/2015 11:00 a.m. California / 2:00 p.m. New York
12/11/2014 8:00 a.m. California / 11:00 a.m. New York
12/10/2014 8:00 a.m. California / 11:00 a.m. New York
3/31/2015 11:00 a.m. California / 2:00 p.m. New York
Quick Poll
The Continuing Education Center offers engineers an entirely new way to get the education they need to formulate next-generation solutions.
Mar 30 - Apr3, Getting Hands-On with Cypress’ PSoC
SEMESTERS: 1  |  2  |  3  |  4  |  5  |  67


Focus on Fundamentals consists of 45-minute on-line classes that cover a host of technologies. You learn without leaving the comfort of your desk. All classes are taught by subject-matter experts and all are archived. So if you can't attend live, attend at your convenience.
Learn More   |   Login   |   Archived Classes
Twitter Feed
Design News Twitter Feed
Like Us on Facebook

Sponsored Content

Technology Marketplace

Copyright © 2015 UBM Canon, A UBM company, All rights reserved. Privacy Policy | Terms of Service