Elizabeth M
User Rank
Blogger
Simple fix
Elizabeth M   10/29/2013 11:18:22 AM
NO RATINGS
It's amazing sometimes how the simplest fix can be the solution to a perplexing problem. Such is the case in this example. Thanks for sharing, as it certainly could inspire other engineers not to overthink a puzzling problem in the future and perhaps find the solution where they least expect it.

Rob Spiegel
User Rank
Blogger
Re: Simple fix
Rob Spiegel   10/29/2013 2:48:20 PM
NO RATINGS
Good point, Elizabeth. We see this quite often with the Sherlocks. The simplist solution -- often overlooked because it's so simple -- is often the answer.

far911
User Rank
Silver
Re: Simple fix
far911   10/29/2013 11:47:31 PM
NO RATINGS
As stated common sense is not very common among common people.

William K.
User Rank
Platinum
Re: Simple fix
William K.   10/30/2013 9:50:23 AM
NO RATINGS
Rob, the statement about simple solutions mostly applies to simple problems. How often do we find that "For each complex problem there is a simple solution..... and it is usually wrong". Of course, many complex problems appear complex because they are not really understood, which allows all sorts of wrong conclusions and incorrect assumptions to develop.

In this vent posting it was not really clear as to why the heat rise problem was suddenly arising, when it had not been there before. While cooling the enclosure stopped the symptom it was not really solving the problem that something had changed.  It was a good work-around, but it was not a solution. 

Rob Spiegel
User Rank
Blogger
Re: Simple fix
Rob Spiegel   10/30/2013 2:32:41 PM
NO RATINGS
That's funny, William K. I laughed out loud. You're absolutely right. You can cool the cabinet, but the real problem is why the cabinet was getting hot.

William K.
User Rank
Platinum
Re: Simple fix
William K.   10/30/2013 2:42:27 PM
NO RATINGS
OR, why was the heat rise causing a power supply problem. I replaced one which had a lot of small capacitors which the leakage changed as it got hot and the voltage drifted. Cheaper to replace with a new supply than to replace all of the drifting parts.

Rob Spiegel
User Rank
Blogger
Re: Simple fix
Rob Spiegel   10/30/2013 3:48:54 PM
NO RATINGS
That makes sense, William K. Sometimes all you really need to do is solve the effect of the problem.

Elizabeth M
User Rank
Blogger
Re: Simple fix
Elizabeth M   10/31/2013 4:08:49 AM
NO RATINGS
That's a very good point, William K. I didn't even think of that. Getting to the root of an apparently "simple" problem is really the only true way to actually solve it.

taimoortariq
User Rank
Gold
Re: Simple fix
taimoortariq   10/31/2013 1:26:13 AM
NO RATINGS
I agree, I have heard alot of instances in which engineers spent hours over complicating the solutions, and figuring out the solution in the most indirect ways. On the other hand technicians coming up with the direct solution in minutes. A great way to start with any problem is definitely to check out the most basic problem a system can have.

Ann R. Thryft
User Rank
Blogger
The doctor is in
Ann R. Thryft   10/29/2013 12:50:08 PM
NO RATINGS
This somehow reminds me of a Rube Goldberg system, where mechanical actions have unexpected consequences. I've also call it the "doctor is in" phenomenon: Before finding out what the problem is, it stops happening when someone who can fix it shows up.

Measurementblues
User Rank
Silver
Just venting
Measurementblues   10/30/2013 8:45:47 AM
NO RATINGS
One day in the 1980s, my wife called in a panic because our "portable" (read luggable) computer started going haywire. Keyboard characters were coming up wrong and things like that. I was at work at the time so it had to wait until I got home. The problem was obvious to me. She had put a book right up against the computer's vent, causing a temperature increase. Removing the book cleared the vent and all was well.

taimoortariq
User Rank
Gold
obvious solution
taimoortariq   10/31/2013 1:21:43 AM
NO RATINGS
Some times are ignorance of the obvious solution can become a problem. We have a habbit of going to complicate things ourselves. It is always good to start with the most basic checks then to assume what might have gone wrong.

Elizabeth M
User Rank
Blogger
Re: obvious solution
Elizabeth M   10/31/2013 4:05:25 AM
NO RATINGS
That's good advice, taimoortariq. We tend to blow up problems into something bigger than we are before taking the time to see what might be wrong at a basic level. I think this is something that's not unique to engineering but can apply to many other situations as well!

a.saji
User Rank
Silver
Re: obvious solution
a.saji   10/31/2013 4:59:45 AM
NO RATINGS
@taimoor: True but that is where you need a back-up plan. When you have a back-up most often you do get the 1st one right since you tend to think all the  IF possibilities.  

William K.
User Rank
Platinum
Re: obvious solution
William K.   10/31/2013 9:44:11 AM
NO RATINGS
a.saji, a backup plan is ALWAYS a good idea, no question about that. Sometimes that plan is just the work-around for the problem that does not cure it b8ut allows one to continue. Other times a backup plan is a separate and different solution completely. And I am wondering what branch of engineering you are involved with, you often have very good comments.

taimoortariq
User Rank
Gold
Re: obvious solution
taimoortariq   10/31/2013 11:49:50 PM
NO RATINGS
A.saji that is also a great way to strategize your solution to the problems.

Chartrain
User Rank
Iron
Why cool the cabiney when you can cool the building
Chartrain   11/1/2013 4:34:41 PM
NO RATINGS
A similar albeit expensive solution involved a printer on an SMT production line. The printer would begin to falter and eventually shut down. 

The theroy was that the printer controls were overheating so the enclosure was opened and a fan placed to blow on the electronic control cards. After that failed as a solution, the 2 inch exhaust duct was replaced with an 8 incher, almost sucking the machine off the floor. Still no good so the entire several thousand square foot room was chilled to almost artic temperatures with a month of 100 plus days outside. The electricirty bill alone I'm sure was more than the cost of the printer.

After pleas with the owner, it was finally agreed to PAY for a service tech to look at the machine. Within a short time, the problem was found ( a miswired interface between machines) and all went back to normal. 

Meanwhile the months the room was under artic conditions, the process went to hell in a hand cart as solder paste is meant to  be printed at room temp (think peanut butter in a freezer and trying to spread on bread)

The penny wise pound foolish attempt at a go around was indeed very expensive in the end.

mr_bandit
User Rank
Iron
my father was an ET in the navy
mr_bandit   11/1/2013 9:08:45 PM
NO RATINGS
My father told me a similar story about a cabinet he worked onboard ship when he was a Navy ET. In his case, he mounted a big fan after having the machine shop hop out an appropriate hole, and sucked air thru the cabinet.


Of course, the only logical place for the output was wher a K-Krusty old Chief (a redundent description) liked to stand....

 

mr_bandit
User Rank
Iron
Re: my father was an ET in the navy
mr_bandit   12/2/2013 4:25:57 PM
NO RATINGS
I had a problem with a video recording system I put together for a client. I had a server case (tower that would mount in a 19" rack). The front bay held a bunch of disc drives. I had a high failure rate of drives - excessive read counts. I looked at how tightly packed the drives were. Ended up taking them out, re-drilling the holes to space the drives out, mounted three fans that just blasted air on and between the drives. Worked like a charm, even if I got comments from the MechE's.

jhankwitz
User Rank
Platinum
Cooling Fan Junkie
jhankwitz   11/18/2013 10:09:30 AM
NO RATINGS
Having witnessed electronic equipment failure after failure over the years due to excessive heat, I've become a cooling fan junkie.  My wife calls me addicted, compulsive, and anal.  I buy the little 4" 120V quiet fans and mount them by every computer, hard drive, digital display, and AV device.  It must be working because I've never had another device failure since.  Every custom design or install I do starts with figuring out how and where the cooling fan will be mounted.

Latest project was cooling my 27" iMac.  Built a simple box using 1/4 inch plywood with a 3" back and pie shaped sides.  Installed the fan into the plywood and attached the assembly under my desktop below the computer.  Drilled 3/8 inch holes 1 inch apart through my desktop and directly under the edge of the computer/monitor.  It's amazing how much cooler the computer runs, 24/7.

Partner Zone
More Blogs from Sherlock Ohms
Sherlock Ohms highlights stories told by engineers who have used their deductive reasoning and technical prowess to troubleshoot and solve the most perplexing engineering mysteries.
Sherlock Ohms highlights stories told by engineers who have used their deductive reasoning and technical prowess to troubleshoot and solve the most perplexing engineering mysteries.
Sherlock Ohms highlights stories told by engineers who have used their deductive reasoning and technical prowess to troubleshoot and solve the most perplexing engineering mysteries.
Sherlock Ohms highlights stories told by engineers who have used their deductive reasoning and technical prowess to troubleshoot and solve the most perplexing engineering mysteries.
Sherlock Ohms highlights stories told by engineers who have used their deductive reasoning and technical prowess to troubleshoot and solve the most perplexing engineering mysteries.
Design News Webinar Series
7/23/2014 11:00 a.m. California / 2:00 p.m. New York
7/17/2014 11:00 a.m. California / 2:00 p.m. New York
6/25/2014 11:00 a.m. California / 2:00 p.m. New York
5/13/2014 10:00 a.m. California / 1:00 p.m. New York / 6:00 p.m. London
Quick Poll
The Continuing Education Center offers engineers an entirely new way to get the education they need to formulate next-generation solutions.
Jul 21 - 25, Design Products With Bluetooth Low Energy
SEMESTERS: 1  |  2  |  3  |  4  |  5  |  6


Focus on Fundamentals consists of 45-minute on-line classes that cover a host of technologies. You learn without leaving the comfort of your desk. All classes are taught by subject-matter experts and all are archived. So if you can't attend live, attend at your convenience.
Next Class: August 12 - 14
Sponsored by igus
Learn More   |   Login   |   Archived Classes
Twitter Feed
Design News Twitter Feed
Like Us on Facebook

Sponsored Content

Technology Marketplace

Copyright © 2014 UBM Canon, A UBM company, All rights reserved. Privacy Policy | Terms of Service