Blogs
Made by Monkeys

Sparks Fly Over Bad Oven Design

NO RATINGS
View Comments: Threaded|Newest First|Oldest First
naperlou
User Rank
Blogger
Dangerous situation
naperlou   6/14/2013 9:40:24 AM
NO RATINGS
Noor, they were probably trying to save money on the switch.  Not taking into account the failure mode you ran into, they figured that the 110 volts on the element were not as problem.  Not very smart, and how did they pass UL testing?

 

Charles Murray
User Rank
Blogger
Re: Dangerous situation
Charles Murray   6/14/2013 2:14:28 PM
NO RATINGS
Noor, it's interesting that the manufacturer would not (or maybe could not) answer your questions. Where safety is concrned, a good manufacturer should be more cooperative.

tekochip
User Rank
Platinum
Re: Dangerous situation
tekochip   6/14/2013 8:59:19 PM
NO RATINGS
It's been a while since I've done an oven, but a double line break was not required in the US, however was required in Canada.  We used to have two seperate to handle the destination and save money when it was domestic.

William K.
User Rank
Platinum
Re: Dangerous situation
William K.   6/17/2013 9:01:00 AM
NO RATINGS
The correct way to switch power, at least by JIC standards for industrial equipment, is to break all the non-neutral lines. I think that is also required by the NEC. So a control switch in one side of the 240 volt lines is a poor excuse for a control method in the US. In the UK the power is a basic 230 volts with one side as neutral, which is usually also grounded. So in those systems only breaking the "hot" side would be quite adequate, and would not constitute any hazard in a polarized-connector installation. But with the basic voltage being 230 instead of 120, I am far more likely to disconnect the power before opening anything. But that is a separate issue.

TJ McDermott
User Rank
Blogger
Re: Dangerous situation
TJ McDermott   6/17/2013 10:21:00 AM
NO RATINGS
tekochip, that company's policy is an invitation to an unwinnable lawsuit.  At least, that's the argument posed by most companies selling industrial safety components.  The plaintiff's argument would question why a less safe product was sold in one country and a more-safe product in another.

tekochip
User Rank
Platinum
Re: Dangerous situation
tekochip   6/17/2013 11:11:25 AM
NO RATINGS
 I haven't worked on an oven in almost ten years so this may have changed, but the products I worked on went through all agency approvals for US and Canada.  Only Canada required a double line break.  The operational standard was to use one relay as a "safety" and two other relays to perform the actual cycling for the bake and broil elements.  Both relays were single line break and this was common for Whirlpool, Kenmore, KitchenAid, Maytag...... well, every brand I ever saw. 


Rob Spiegel
User Rank
Blogger
Re: Dangerous situation
Rob Spiegel   6/17/2013 11:25:19 AM
NO RATINGS
Tekochip, I would guess these measures would have prevented the problem in this story. Right? If so, what happened to those standards?

tekochip
User Rank
Platinum
Re: Dangerous situation
tekochip   6/17/2013 12:21:24 PM
NO RATINGS
Just as in the story, it's a single line break, so one phase can arc to the holder if that's where the fault is in the element.

Tool_maker
User Rank
Platinum
Re: Dangerous situation
Tool_maker   6/17/2013 4:26:51 PM
Rob. I wish you would ask for and publish the manufacturers name in these cases. As another poster responded, we do not even know the country of origin for the writer, much less the appliance.

Ann R. Thryft
User Rank
Blogger
Re: Dangerous situation
Ann R. Thryft   6/19/2013 12:50:38 PM
NO RATINGS
Would it be possible at least for the author to tell us what make and model oven this occurred in? A manufacturer who not only makes such shoddy products but won't reveal basic information that the author requested is one I want to avoid.



Noor Khalsa
User Rank
Iron
Re: Dangerous situation
Noor Khalsa   6/19/2013 3:10:36 PM
NO RATINGS
Made by Amana.

Keldawwg
User Rank
Gold
Re: Dangerous situation
Keldawwg   6/19/2013 5:23:08 PM
NO RATINGS
Yeah, I would have guessed that it was one of Whirlpool's products... But it sounds like they are all doing this kind of crap...

And they wonder why Samsung, Lucky Goldstar, Bosch, Miele and Electrolux are taking market share away from them them... And Fisher & Paykel are getting more popular. Not that these companies all make great products... But they all make OK products... (Well, in my opinion Miele makes some great products!)

Whirlpool is to appliances like Fram is for car parts... They are a brand I will never buy again...

I can remember a time when they both made decent products... But I'm pretty old.

I heard a rumor that GE was making slightly better quality than the junk they hawked a few years ago... But I have not seen any hard evidence yet that it's true... I bought a 12 year guaranteed water heater at Home Depot (Labeled "Best" on the sign...) and it flooded my garage 14 months after I installed it. (At least I had it in a pan that dumped towards the garage... Otherwise it would have flooded my house...) That left a sour taste in my mouth...

 

Keldawwg
User Rank
Gold
Re: Dangerous situation
Keldawwg   6/19/2013 5:28:29 PM
NO RATINGS
And I do know a guy that works at UL in San Jose... If I called him a monkey, I'd have to make my apologies next time I go to the zoo... 

Ann R. Thryft
User Rank
Blogger
Re: Dangerous situation
Ann R. Thryft   6/19/2013 5:51:46 PM
NO RATINGS
Noor, thank you for posting the company name. It seems that the quality of once-great brands has really dropped way, way down. I bought a Sears Kenmore oven and fridge and a fairly low-end GR washer and dryer about 12 years ago. I still have them, and the Sears machines, in particular, still work great. I've grumbled here occasionally about the GE knobs and membrane keypads, but the basic machine parts still work well. I dread the day when I have to replace them.

Noor Khalsa
User Rank
Iron
Re: Dangerous situation
Noor Khalsa   6/19/2013 7:34:49 PM
NO RATINGS
I just found a Whirlpool oven schematic online that does the same thing - switches L2, but not L1. So I think that it is not required by UL, and that most, if not all, all manufacturers do it. Admittedly, you don't pull the element out for cleaning like a stovetop burner. Still, I feel nervous when I can come into contact with an element that has one side hot just by cleaning my oven, now that I've seen what can happen when the element breaks down.

Ann R. Thryft
User Rank
Blogger
Re: Dangerous situation
Ann R. Thryft   6/20/2013 12:16:06 PM
NO RATINGS
Noor, I find it difficult to believe that that situation is OK with UL. It's far too dangerous, and that's supposed to be what the lab is about, wouldn't you think?

Noor Khalsa
User Rank
Iron
Re: Dangerous situation
Noor Khalsa   6/20/2013 6:52:41 PM
NO RATINGS
Yes, I've seen it be dangerous. But what really irked me was how the manufacturer practically went out of their way to NOT give me any help on this. They were so polite and so utterly useless. They must think it's dangerous for them just to talk about it.

Ann R. Thryft
User Rank
Blogger
Re: Dangerous situation
Ann R. Thryft   6/21/2013 1:27:42 PM
NO RATINGS
I'm with you on that, which is why I'm asking about UL. There are supposed to be legal and/or monetary consequences for dangerous electrical products/components. That makes me wonder if the Whirlpool machine with the same switching pattern may also be violating UL standards. Or did something happen to consumer product oversight?

Noor Khalsa
User Rank
Iron
Re: Dangerous situation
Noor Khalsa   6/21/2013 5:24:03 PM
NO RATINGS
I searched out some more schematics, and the majority of them only switch one side of the oven heater element. I'm sure that some of these models had to be UL approved, so I guess it's just the industry's dirty little secret. And you really can't get electrocuted touching a live heater element if it is dry and in good condition. But the insulation layer is constantly subject to high temperatures, so I still think it's a bad design for a  consumer appliance. I'm glad that I got such a good response to the article here. Maybe things will change.

Rob Spiegel
User Rank
Blogger
Re: Dangerous situation
Rob Spiegel   6/24/2013 11:08:58 PM
NO RATINGS
Hey Tool_Maker. The author, Noor, is responding to postings at this point, so you may want to repost your question if it hasn't already been answered.

Cabe Atwell
User Rank
Blogger
Re: Dangerous situation
Cabe Atwell   6/27/2013 11:06:38 PM
NO RATINGS
I wonder if it was made by Soni, Whirlpond, Samsong, Magnetbox or other questionable manufacturer with a dubious sounding name.

C

Noor Khalsa
User Rank
Iron
Re: Dangerous situation
Noor Khalsa   7/9/2013 3:39:16 PM
NO RATINGS
Cabe, Toolmaker - the mfg in this case was Amana, but I found schematics from others, such as Whirlpool, who do the same thing: only switch one side of the oven element. And I'm located in the USA, where UL approves such things, apparently.

Battar
User Rank
Platinum
Meanwhile, on the continent...
Battar   6/17/2013 8:49:30 AM
A single line switch would not normally be a problem when the mains supply is 230V, at least not in the UK or in the country where I live. But in many EU countries they use the Schuko type plug, which is reversible, meaning you get the live mains on the right hand pin on Mondays, Thursdays, and Saturdays, and on the left pin any other day of the week you plug it in.

kcp
User Rank
Silver
Double switch should be necessary
kcp   6/17/2013 8:57:02 AM
Most heating elements in an oven in the US are 220V, which means both hot sides are connected (110V each, opposite phase).  If only one side is switched, the element is still live because it is connected to the other hot line.  I'm surprised this design passed UL.

Amclaussen
User Rank
Platinum
Re: UL being invaded by Monkeys
Amclaussen   6/19/2013 12:21:36 PM
NO RATINGS
The answer is that, because of their frantic hyperactivity (which is interpreted by CEO's and MBA's as "productivity"; and their low demanded salaries, many workplaces at UL had been asigned to Monkeys.

RBedell
User Rank
Gold
If you think that is fun...
RBedell   6/17/2013 9:07:40 AM
Usually, appliances have a diagram/schematic on the back or on the inside of a panel.  So, if you think flying sparks are fun then check out the electric dryer for a shocking good time.

I have worked on a few and was stunned.  They use 220Vac as well. But, the motor is not 220V,...it is 110V!  So, on three wires, where do they get the tap for 110V?  GROUND!!!  Thats right.  They use the ground wire; the same one that is connected to the chassis.  Turns out this is not true in all cases.  Some dryers have the option for 4-wire plugs (which provides the neutral).  But even they have the option to be wired for 3-wire plugs.  My research showed that mobile homes requires 4-wire  but a regular house does not.

Safety seems to be suffering in the name of profit; or is simply being ignored.

OLD_CURMUDGEON
User Rank
Platinum
Re: If you think that is fun...
OLD_CURMUDGEON   6/17/2013 9:51:39 AM
I addressed this topic in another similar blog last week, but will repeat it for information purposes.

You ARE correct about the 3-wire & 4-wire services to electric ranges & clothes dryers.  Up until recently, the NEC allowed the connection of either an electric range OR a clothes dryer with 3-wire in the application of SINGLE FAMILY DWELLINGS only!

In the case of the clothes dryer either 10/2 ROMEX or BX w/GND were allowed, the GND conductor ALSO serving as the "neutral" for the power to controls, solenoids, motors.  The NEMA codes for these devices is 10-30 (R) & (P), where the (R) & (P) stands for Receptacle & Plug, respectively.

And, it is true that in MOBILE HOME installations, the feeds MUST have been w/ 10-3 /w GND cable.  The NEMA dodes for these devices is 14-30 (R) & (P).

The latest NEC code however has changed the requirement so that the frame of the appliance is connected to the GROUNDING conductor (bare, green or  yellow/green), and the two lines & neutral (white) are connected to the terminal block provided on the rear of the appliance.

This change also affects single unit electric cook ranges, except the NEMA designations are 10-50 (R) & (P) for the old-style connections and,

14-50 (R) & (P) for the new code revision requirement.

One final note:  Since both electric ranges AND clothers dryers are considered "permanent" appliances from the code's perspective, it is now & has always been that the feed cable may be directly connected to the appliance.  However, some installers prefer the added convenience of using a cordset w/ a permanently installed receptacle device, either surface mounted OR recessed in an appropriate device box. 

Critic
User Rank
Platinum
Assumptions!
Critic   6/17/2013 10:00:51 AM
NO RATINGS
It seems that some of us have made assumptions that may be flawed.  First, not all appliances have a wiring diagram included, but I sure do appreciate this when a manufacturer is nice enough to include one.  It's not required!  Second, we should not assume that the author is located in the US!  This person has an Arabic (assumption) last name!  Third, UL listing is not required everywhere, so there is no reason to assume that the oven passed UL testing!  Last, we don't know where the manufacturer is located, so we should not assume that it should behave like most US manufacturers!

 

mjones0916
User Rank
Iron
Heater Controls
mjones0916   6/19/2013 8:39:45 AM
NO RATINGS
I work in industry and it is common practice on heater control circuits to switch only one of the hot legs.  In most three phase heater applications only two out of the three phases are controlled leaving the third continuously hot.  Most of these designs also include another control element in the line controlled by an over-temperature sensor as a safety in case the control element fails closed.  The safety contactors are usually conventional relays as opposed to solid state contactors.  The reason this is done is cost and I would assume that's the reason they've done it on the oven.

bobjengr
User Rank
Platinum
SPARKS
bobjengr   6/22/2013 8:27:29 PM
NO RATINGS
Excellent post Noor.  I retired from the appliance industry before starting my company and remember the very same issues from earlier times.   Now, UL requires "double line break" for 220 VAC heating elements and circuits.  At one time, one leg remained "hot" even after an element or switch malfunctioned.  One of the greatest problems with electric elements, bake and broil, is entrained moisture.  Moisture enters and when heated, expands causing ruptures in the tubular element.   The MgO acts as a "sponge" thus causing issue when water is present.  In the newer ranges, DLB systems will solve this problem.

Partner Zone
More Blogs from Made by Monkeys
Made by Monkeys highlights products that somehow slipped by the QC cops.
Made by Monkeys highlights products that somehow slipped by the QC cops.
Made by Monkeys highlights products that somehow slipped by the QC cops.
Made by Monkeys highlights products that somehow slipped by the QC cops.
Made By Monkeys highlights products that somehow slipped by the QC cops.
Design News Webinar Series
12/11/2014 8:00 a.m. California / 11:00 a.m. New York
12/10/2014 8:00 a.m. California / 11:00 a.m. New York
11/19/2014 11:00 a.m. California / 2:00 p.m. New York
11/6/2014 11:00 a.m. California / 2:00 p.m. New York
Quick Poll
The Continuing Education Center offers engineers an entirely new way to get the education they need to formulate next-generation solutions.
Jan 12 - 16, Programmable Logic - How do they do that?
SEMESTERS: 1  |  2  |  3  |  4  |  5  |  67


Focus on Fundamentals consists of 45-minute on-line classes that cover a host of technologies. You learn without leaving the comfort of your desk. All classes are taught by subject-matter experts and all are archived. So if you can't attend live, attend at your convenience.
Learn More   |   Login   |   Archived Classes
Twitter Feed
Design News Twitter Feed
Like Us on Facebook

Sponsored Content

Technology Marketplace

Copyright © 2014 UBM Canon, A UBM company, All rights reserved. Privacy Policy | Terms of Service