naperlou
User Rank
Blogger
but is it safety certified
naperlou   9/17/2012 10:43:21 AM
NO RATINGS
Galen, you seem to have found a good solution to your problem.  The only question I have in these instances is that of certification.  Is there an issue with that when field modifications are made to the control system?

Charles Murray
User Rank
Blogger
Optional feature?
Charles Murray   9/17/2012 5:11:05 PM
NO RATINGS
"In the absence of pushbuttons on the LCP, we had to carry a handheld version of the TWC transmistter out to a particular inductive loop in order to enter a request. Considering the inconvenience of having to walk out to the yard with the handheld, we decided to add real control capability to the panel." I don't doubt this is the case, but I don't understand why suppliers do things like this. Seems like it ruins the good will between the supplier and the customer.

Tim
User Rank
Platinum
Specifications?
Tim   9/17/2012 7:39:26 PM
NO RATINGS
It would be interesting to know if this item was specified without the pushbuttons or if was an oversight by the manufacturer.  It might be a case of trying to staying below budget on a new installation

RailroadGeek
User Rank
Iron
Re: Specifications?
RailroadGeek   9/18/2012 12:32:39 AM
NO RATINGS

The original specifications for the installation were written by a private consultant to the agency and supposedly reviewed by the agency's own project management  team (and any other parties having a stake in the final product). Somehow, this issue wasn't caught and corrected before the contractor got the notice to proceed.

It's also interesting to note there is one track switch (out of the 16 total in the system) which is manually controlled (it is not provided with motorized operation) and cannot be automatically aligned by a request through the TWC or PLC.

However it does have position feedback to the PLC and if the switch is not properly aligned for the requested route, the PLC will reject the request and the signal light will be stuck on a red "X". In that case, the yard attendant has to use a switch iron (a pry bar) to flip the switch to the correct position and allow the signal to turn green.

The price tag on the entire control system was about $1.5 Million and I believe that adding the option for pushbuttons (and one additional motorized switch) would have added only $50,000.00 to the total cost.

My guess is that the oversight may have been due to the usual culprit – the gremlin of mismanagement in government or the bean counters (rather than just the designers) may have had their say in the final outcome.

That's why I thought it qualified for the Made By Monkeys column!!!

TJ McDermott
User Rank
Blogger
Re: but is it safety certified
TJ McDermott   9/18/2012 11:15:01 AM
NO RATINGS
Naperlou, you voiced my first question.  How was this field modification approved for safety?  Was it approved at all?

RailroadGeek
User Rank
Iron
Re: but is it safety certified
RailroadGeek   9/18/2012 9:39:27 PM
NO RATINGS

Regarding the issue of approvals and safety certification, all modifications to a rail signaling system must be approved by the agency's Bureau Of Engineering. The process also provides for "peer review" before a change order is finally issued.

The state division of railway safety also requires a comprehensive report of any modifications to signaling systems and the results of the final testing.

The addition of local control involved the "Non-Vital" *** portion of the system which does not directly execute any safety critical functions.  

*** the actual safety critical functions of a railroad signal system are referred to as "Vital" and non-safety critical are classified as "Non-vital". The PLC used for railroad signaling is specially built for that application and actually contains 4 PLCS working on the checked redundant principle. The first PLC where requests are inputed is the non-vital level.

amoninous
User Rank
Silver
CONTROL PANEL WIRING
amoninous   9/19/2012 12:52:07 PM
NO RATINGS
I had a very similar situation some 60 years ago when wiring the control panel for my LIONEL set.  It was quite a challenge then since (redundant) PLCs had not yet been invented, but I muddled through despite this major limitation.

warren@fourward.com
User Rank
Platinum
Re: Optional feature?
warren@fourward.com   9/20/2012 4:20:34 PM
NO RATINGS
Someone really dropped the ball.  I would have thought in the design meetings this would have been discussed.  OR, they didn't understand the customer's needs to begin with and just did the basics.  It is so important that the customer's needs are top priority.  If you build it, they may come and be disappointed...

 

Tool_maker
User Rank
Platinum
Re: Specifications?
Tool_maker   10/1/2012 4:53:06 PM
NO RATINGS
  There are occasions when the biggest hurdle engineering has to vault is purchasing. I remember a story of an astronaut feeling uneasy when he stopped to realize he was sitting atop a space vehicle all made by "The Losest Bidder".

wbswenberg
User Rank
Gold
Its not what you wanted but it is something.
wbswenberg   10/3/2012 4:47:42 PM
NO RATINGS
I was posted to the lab to support my share of cruise missle verification.  We had accomplised the B-52 version.  This was the OAS B-1 version in the B-52 as Carter killed the B-1.  Note that nothing the military wants stays dead.  We had one of the three system compters.  There were three in the system as they voted and checked each other.  But the system as not working.  The simulation was not working and the guy responsible was shuffling the cards in the Harris /5.  He got a lot of greif for doing that becuase the was a precedence - order that the cards were called.  Hey at least he was trying something.  Asked about this and that trying to figure something out - any thing at all.  We were looking at the three ports at OAS computer.  Remember the three computers are tied to gether.  The first port was used as directed.  Well let's just try the other ports how would we do that.  Just unplug the cable and plug it into #2.  And the computer started working.  The reason as I under stood it.  The primary expected checking by the secondary and tertiary computer.  But if it was not working then the secondary would takeover.  And if it was the last computer it would run alone.  Then I had to go to work.

Page 1/2  >  >>
Partner Zone
More Blogs from Made by Monkeys
Made By Monkeys highlights products that somehow slipped by the QC cops.
Made By Monkeys highlights products that somehow slipped by the QC cops.
Made By Monkeys highlights products that somehow slipped by the QC cops.
Made By Monkeys highlights products that somehow slipped by the QC cops.
Made By Monkeys highlights products that somehow slipped by the QC cops.
Design News Webinar Series
9/10/2014 11:00 a.m. California / 2:00 p.m. New York
7/23/2014 11:00 a.m. California / 2:00 p.m. New York
7/17/2014 11:00 a.m. California / 2:00 p.m. New York
6/25/2014 11:00 a.m. California / 2:00 p.m. New York
Quick Poll
The Continuing Education Center offers engineers an entirely new way to get the education they need to formulate next-generation solutions.
Sep 22 - 26, MCU Software Development – A Step-by-Step Guide (Using a Real Eval Board)
SEMESTERS: 1  |  2  |  3  |  4  |  5  |  6


Focus on Fundamentals consists of 45-minute on-line classes that cover a host of technologies. You learn without leaving the comfort of your desk. All classes are taught by subject-matter experts and all are archived. So if you can't attend live, attend at your convenience.
Next Class: September 30 - October 2
Sponsored by Altera
Learn More   |   Login   |   Archived Classes
Twitter Feed
Design News Twitter Feed
Like Us on Facebook

Sponsored Content

Technology Marketplace

Copyright © 2014 UBM Canon, A UBM company, All rights reserved. Privacy Policy | Terms of Service