GlennA
User Rank
Gold
hydraulics vs working applications
GlennA   6/18/2012 9:34:11 AM
NO RATINGS
Hydraulic robots have become few and far between (in my experience).  The rationale that I was told was because of the automotive industry.  Automotive is a big user of robots.  When robots were hydraulic, 3 (sometimes 4) trades were required to work on them.  The electrician for the controller, the millwright for the hardware, or for tooling issues (sometimes a tool-maker also), and a plumber for the hydraulics.  The all-electric robot eliminated one trade from that group.

The manipulator arm on the Space Shuttle was a 'hydraulic' application = high torque and low speed.  Clean-room issues i.e. hydraulic oil leaks would have been a problem.  A broken wire does not 'leak' electricity in the same way a broken hose would leak oil.

One thing that I think is missing from your hydraulic system is the unloading valve.  Many of the machines that I have worked on had an unloading valve to direct flow to the tank at low pressure to reduce heating when the system was in standby.

TJ McDermott
User Rank
Blogger
Each has its place
TJ McDermott   6/18/2012 1:57:58 PM
NO RATINGS
Hydraulic vs. Electric is not a winner-take-all competition.  Each has roles in which it is better suited.  One of my customers offers products that use either one or the other as the prime mover, depending on application.  It means more engineering work for my customer, but their end users are happy with a solution that fits their needs, rather than adjusting their needs to fit a single solution.

 

Alex.W
User Rank
Iron
Re: hydraulics vs working applications
Alex.W   6/19/2012 1:51:55 PM
NO RATINGS
I think the variable speed drive would negate the need for an unloading valve, assuming there were no other loads requiring driving while this subset of the machine is in standby.

crob09
User Rank
Iron
Re: hydraulics vs working applications
crob09   6/19/2012 4:44:37 PM
NO RATINGS
No you still need an "unloading valve" or Bypass valve, no different from an electric forklift. The PTO is variable speed and the unloading valve is still necessary when the load is too great, or if the cylinder has reached it's maximum travel. Otherwise you would burn out the PTO or motor.

Rob

http://www.whatisacnc.com

GlennA
User Rank
Gold
Nomenclature
GlennA   6/20/2012 8:43:31 AM
NO RATINGS
An unloading valve is not the same as a relief valve or a regulating valve.  From my training:  An unloading valve is used to direct all flow from the pump to the tank at low pressure to reduce heating, and to allow the electric motor / pump to start under no-load.  A relief valve is used to control maximum system pressure.  When the maximum pressure is reached, the valve opens to direct flow to the tank without reducing the pressure.  A pressure reducing valve, also called a regulating valve, is used to reduce pressure to a segment of the system.  Not everyone that works in hydraulics agrees with the nomenclature that I learned.

Instead of a variable speed motor, I have seen pressure and flow compensating pumps that have a swash plate that is adjusted to reduce the flow from the pump without affecting the pressure, at a constant electric motor speed.

Partner Zone
More Blogs from Guest Blogs
Was Steve Job’s signature outfit of a black turtleneck, jeans, and sneakers the secret behind his success? Maybe, or maybe not, but it was likely an indication of a decision-making philosophy that enabled him to become one of the most successful innovators of all time.
Electromechanical actuators and propulsion system enable the first controlled landing and ascent from a solar system body other than the moon.
Combining energy-saving product design and advanced lithium batteries enables wireless devices to operate maintenance-free for up to four decades.
Hardware-in-the-loop test platforms enable manufacturers to deal with increasing software complexity.
Remember when design decisions for optimizing low-power MCU applications were simple? All you needed to do was select when to put the MCU into the low-power mode and when to wake it up. Once it was awake, you just ran the required code as quickly as possible. Simple, right? Well, these days designing for power efficiency isn’t so simple. Why is that the case?
Design News Webinar Series
2/25/2015 11:00 a.m. California / 2:00 p.m. New York
12/11/2014 8:00 a.m. California / 11:00 a.m. New York
12/10/2014 8:00 a.m. California / 11:00 a.m. New York
11/19/2014 11:00 a.m. California / 2:00 p.m. New York
Quick Poll
The Continuing Education Center offers engineers an entirely new way to get the education they need to formulate next-generation solutions.
Feb 23 - 27, Baremetal C Programming for Embedded Systems
SEMESTERS: 1  |  2  |  3  |  4  |  5  |  67


Focus on Fundamentals consists of 45-minute on-line classes that cover a host of technologies. You learn without leaving the comfort of your desk. All classes are taught by subject-matter experts and all are archived. So if you can't attend live, attend at your convenience.
Learn More   |   Login   |   Archived Classes
Twitter Feed
Design News Twitter Feed
Like Us on Facebook

Sponsored Content

Technology Marketplace

Copyright © 2015 UBM Canon, A UBM company, All rights reserved. Privacy Policy | Terms of Service